MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ajh/hpaf016

Медицинская библиотека · American journal of hypertension · 2025

Accuracy of a Novel High-Throughput "Car Blood Pressure" Measurement Protocol.

Lima Neiberg de Alcantara, Cardozo Shaun, Johnson Andrew, Reed Brian, Korzeniewski Steven, Levy Phillip D, Brook Robert D

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

More than one in three adults with hypertension in the United States are unaware of their condition, highlighting the importance of large-scale screening campaigns. Currently, the identification of hypertension is largely limited to medical settings. To help overcome this barrier, we developed a novel high-throughput screening protocol that measures blood pressure (BP) while patients remain seated in an automobile ("car-BP"). The aim of this study was to provide an initial assessment of the accuracy of car-BP.

METHODS

Three BP readings were determined in a clinic exam room before and after three BP readings were taken while patients were seated in a parked car outside (n = 100 participants). The same validated device model (Omron HEM-907XL) and BP measurement methods adhering to guidelines were used in both scenarios. The average of all 6 clinic readings was compared to the average of the 3 car-BP readings in each individual.

RESULTS

Mean clinic and car-BP readings were 120.9 ± 16.2/78.0 ± 9.9 and 118.9 ± 15.2/76.0 ± 10.0 mm Hg, respectively. The paired mean and absolute mean differences in systolic BP levels between methods were -1.92 mm Hg (95% confidence interval (CI) -3.2 to -0.7 mm Hg) and 4.8 mm Hg (95%CI 3.8 to 5.6 mm Hg), respectively. A total of 85% of participants had both systolic and diastolic BP levels ≤ 10 mm Hg different between measurement scenarios (meeting the a priori determined study primary outcome).

CONCLUSIONS

Car-BP represents an innovative and accessible approach for potential large-scale hypertension screening campaigns.

Для цитирования: Lima Neiberg de Alcantara, Cardozo Shaun, Johnson Andrew, Reed Brian, Korzeniewski Steven, Levy Phillip D, Brook Robert D. Accuracy of a Novel High-Throughput "Car Blood Pressure" Measurement Protocol.. American journal of hypertension. 2025. DOI: 10.1093/ajh/hpaf016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.