A comparison of surgical outcomes with the use of 2 different biodegradable multipoint fixation devices for endoscopic forehead elevation.

Servat J Javier, Black Evan H

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To assess the efficacy and rates of inflammatory cyst formation with the use of 2 different biodegradable multipoint fixation devices, Endotine versus Ultratine, for endoscopic forehead elevation.

METHODS

The charts of 138 patients who underwent endoscopic forehead elevation by the same surgeon (E.H.B.) were reviewed retrospectively. Data regarding patient demographics, type of biodegradable fixation device, loss of fixation in the immediate and late postoperative period, inflammatory cyst formation of the fixation device, additional complications, and reoperation status were collected from the charts. Patients implanted with Endotine and Ultratine were compared postoperatively for early and late loss of elevation (efficacy), inflammatory cyst formation, additional complications, and reoperation rates.

RESULTS

Of the 276 fixation devices implanted (117 Endotine and 159 Ultratine), 11 inflammatory cysts were found, all of them in the Ultratine group (p = 0.0037). Four patients required reoperation due to early loss of fixation. Three of these cases were in the Endotine group, and 1 case was observed in the Ultratine group (p = 0.18). A total of 4 patients had late loss of fixation, all of them in the Ultratine group (p = 0.08). Scalp hypoesthesia and/or dysesthesia beyond the sixth postoperative month were observed in 3.62% of the cases. Postsurgical neuralgia was observed in 2.17%, and focal alopecia was seen in 1.44%.

CONCLUSIONS

The presence of inflammatory cysts with the implantation of the Ultratine device is statistically higher than with Endotine. No statistical significant difference was found in either early or late fixation loss between the 2 groups.

Для цитирования: Servat J Javier, Black Evan H. A comparison of surgical outcomes with the use of 2 different biodegradable multipoint fixation devices for endoscopic forehead elevation.. Ophthalmic plastic and reconstructive surgery. 2012. DOI: 10.1097/iop.0b013e318261169a.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.