Audit of warfarin reversal using a new Octaplex reduced dose protocol.

Hirri H M, Green P J

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Prothrombin Complex Concentrate (PCC) is increasingly used for the emergency reversal of the effects of Vitamin K antagonists due to the increased use of the latter. There is no consensus on dosage protocols for its use. There is evidence that small fixed doses are effective. We report the result of the use of a simple three dose level protocol i.e. 2000 IU for CNS bleeds, 1500 IU for other bleeds and 1000 IU for non bleeders.

METHODS

Data was prospectively collected over a 6 month period on all patients receiving PCC (Octaplex). These included clinical indication, dose given, INR test results, delay in treatment, and patients' demographics.

RESULTS

The protocol was followed in only 40%; 24% were given a larger dose and 35% a smaller dose than we recommended. Despite this the INR was corrected (≤1.5) in 56 (83.6%) out of the 67 patients studied. The average delay in getting INR results was 1 hour 14 minutes and delay between releasing the PCC from blood bank to infusion was 3 hours.

CONCLUSION

A simple three level low fixed dose protocol is cost effective in reversing the majority of patients' anticoagulation. Delay in initiating treatment for the reversal of VKA and adherence to protocols remained problematic.

Для цитирования: Hirri H M, Green P J. Audit of warfarin reversal using a new Octaplex reduced dose protocol.. Transfusion and apheresis science : official journal of the World Apheresis Association : official journal of the European Society for Haemapheresis. 2014. DOI: 10.1016/j.transci.2014.08.024.