MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0300161

Медицинская библиотека · PloS one · 2025

Cardiorespiratory demands of firearms training instruction and 15m shuttle tests in British law enforcement.

Warwick Joseph, Cooper Sophie, Ronca Flaminia

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

Law enforcement agencies require minimum fitness standards to safeguard their officers and training staff. Firearms instructors (FI) are expected to maintain the same standards as their operational counterparts. This study aimed to quantify the daily physiological demands placed on FI.

METHODS

19 FI (45 ± 5 years) completed occupational tasks whilst wearing heart rate (HR) monitors for a minimum 10 days. Maximal oxygen consumption (VO2max) testing was conducted on FI during a treadmill test (TT) and a multistage shuttle test (ST). Linear regression models were used to model the relationship between VO2 and HR throughout the TT. This model was applied to HR data from occupational tasks to infer oxygen consumption. Repeated Measures ANOVAs were used to compare time spent in VO2max equivalent zones throughout.

RESULTS

The VO2max achieved during ST (45.1 ± 5.6 ml/kg/min) was significantly higher than TT (39 ± 3 ml/kg/min) (p = 0.014). Time to exhaustion (TTE) was sooner on ST (06:26 min) compared to TT (13:16 min) (p < .001). FI spent ~85% of occupational time with an oxygen demand ≤20 ml/kg/min (p < .005). The most intense occupational tasks saw FI achieve VO2max ≥30 ml/kg/min, but <40 ml/kg/min.

CONCLUSION

Using ST to assess cardiorespiratory fitness resulted in a quicker TTE and a higher VO2max. Predominantly, FI occupational tasks are low intensity with sporadic exposures requiring a VO2max of >40 ml/kg/min. To safeguard FI from occupational-related cardiorespiratory or long-term health issues, it is intuitive to suggest fitness standards should exceed a VO2max of 40 ml/kg/min.

Для цитирования: Warwick Joseph, Cooper Sophie, Ronca Flaminia. Cardiorespiratory demands of firearms training instruction and 15m shuttle tests in British law enforcement.. PloS one. 2025. DOI: 10.1371/journal.pone.0300161.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.