MedElevator Войти в исследования
← Поиск публикаций

DOI 10.17116/hirurgia20190215

Медицинская библиотека · Khirurgiia · 2019

Thoracoscopic clipping of patent ductus arteriosus: position of surgery in the era of transcatheter procedures.

Arkhipov A N, Omelchenko A Yu, Zubritskiy A V, Khapaev T S, Soynov I A, Ivantsov S M, Pavlushin P M, Bogachev-Prokophiev A V, Karaskov A M

СтатьяПеревод в очереди

Аннотация

AIM: To describe single-center evolution of the procedure and to evaluate the results of thoracoscopic clipping of patent ductus arteriosus (PDA) with diameter over 3,0 mm in term infants weighting over 4,0 kg.

MATERIAL AND

METHODS

Thoracoscopic clipping of PDA has been performed in 140 patients for the period from March 2012 to March 2018 in Meshalkin National Medical Research Center. Mean age was 4.0 years (range 3 months - 13 years), mean body mass index - 15.4±2.2 kg/m2.

INCLUSION CRITERIA: PDA size 3.5-10 mm, Qp/Qs >1,3/1,0, weight 4.0-40 kg. Mean PDA size was 4.6±0.9 mm (range 3.5-8.0 mm), mean pulmonary artery pressure - 34.3±5.8 mm Hg, mean systemic/pulmonary flow Qp/Qs - 1.6±0.3. All patients underwent successful PDA closure through four-port technique under endotracheal general anesthesia and no need for pleural drainage.

RESULTS

Mean procedure time was 24.5±15.5 min. In 29 (20,7%) cases we used titanium clips, in 11 (79.3%) - polymer locking ligating clips. There was 1 conversion to mini-thoracotomy. There were no deaths, bleeding or any other life-threatening complications. 94 (67.1%) patients were weaned from ventilator within operating theatre, in other 46 (32.9%) patients mean ventilation time in ICU was 1.3±1.0 hours. In-hospital postoperative complications: pneumothorax - 2 (1.4%) cases, recurrent laryngeal nerve dysfunction - 1 (0.7%), false croup - 1 (0.7%). There were 2 residual leakages in 2 (1.4%) patients in 10 and 6 months after titanium clip deployment. Both of them underwent transcatheter closure using the coil. Considering these cases all following patients underwent PDA closure by polymer locking ligating clips with no cases of residual leakage.

CONCLUSION

Thoracoscopic PDA closure by polymer locking ligating clip is safe and effective technique for surgical management of PDA with diameter over 3.0 mm in term infants weighting over 4.0 kg.

Для цитирования: Arkhipov A N, Omelchenko A Yu, Zubritskiy A V, Khapaev T S, Soynov I A, Ivantsov S M, Pavlushin P M, Bogachev-Prokophiev A V, Karaskov A M. Thoracoscopic clipping of patent ductus arteriosus: position of surgery in the era of transcatheter procedures.. Khirurgiia. 2019. DOI: 10.17116/hirurgia20190215.