Gregoire Eric, Barquinero Joan Francesc, Gruel Gaetan, Benadjaoud Mohamedamine, Martinez Juan S, Beinke Christina, Balajee Adayabalam, Beukes Philip, Blakely William F, Dominguez Inmaculada, Duy Pham Ngoc, Gil Octávia Monteiro, Güçlü Inci, Guogyte Kamile, Hadjidekova Savina Petrova, Hadjidekova Valeria, Hande Prakash, Jang Seongjae, Lumniczky Katalin, Meschini Roberta, Milic Mirta, Montoro Alegria, Moquet Jayne, Moreno Mercedes, Norton Farrah N, Oestreicher Ursula, Pajic Jelena, Sabatier Laure, Sommer Sylwester, Testa Antonella, Terzoudi Georgia, Valente Marco, Venkatachalam Perumal, Vral Anne, Wilkins Ruth C, Wojcik Andrzej, Zafiropoulos Demetre, Kulka Ulrike
Аннотация
MATERIALS AND METHODS: Blood samples were irradiated at three different doses, 1.8, 0.4 and 0 Gy (samples A, C and B) with 4-MV X-rays at 0.5 Gy min-1, and sent to the participant laboratories. Each laboratory was requested to blindly analyze 500 cells per sample and to report the observed frequency of dicentric chromosomes per metaphase and the corresponding estimated dose.
RESULTS: This ILC demonstrates that blood samples can be successfully distributed among laboratories worldwide to perform biological dosimetry in case of a mass casualty event. Having achieved a substantial harmonization in multiple areas among the RENEB laboratories issues were identified with the available statistical tools, which are not capable to advantageously exploit the richness of results of a large ILCs. Even though Z- and U-tests are accepted methods for biodosimetry ILCs, setting the number of analyzed metaphases to 500 and establishing a tests' common threshold for all studied doses is inappropriate for evaluating laboratory performance. Another problem highlighted by this ILC is the issue of the dose-effect curve diversity. It clearly appears that, despite the initial advantage of including the scoring specificities of each laboratory, the lack of defined criteria for assessing the robustness of each laboratory's curve is a disadvantage for the 'one curve per laboratory' model.
CONCLUSIONS: Based on our study, it seems relevant to develop tools better adapted to the collection and processing of results produced by the participant laboratories. We are confident that, after an initial harmonization phase reached by the RENEB laboratories, a new step toward a better optimization of the laboratory networks in biological dosimetry and associated ILC is on the way.