The Journal of thoracic and cardiovascular surgery · 1998
Left ventricular dysfunction after open repair of simple congenital heart defects in infants and children: quantitation with the use of a conductance catheter immediately after bypass.
Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chaturvedi R R, Lincoln C, Gothard J W, Scallan M H, White P A, Redington A N, Shore D F
Аннотация
OBJECTIVE: Quantification of myocardial injury after the simplest pediatric operations by load-independent indices of left ventricular function, using conductance and Mikro-Tip pressure catheters (Millar Instruments, Inc., Houston, Tex.) inserted through the left ventricular apex.
METHODS: Sixteen infants and children with intact ventricular septum undergoing cardiac operations had left ventricular function measured, immediately before and after bypass. Real-time pressure-volume loops were generated by conductance and Mikro-Tip pressure catheters placed in the long-axis via the left ventricular apex, and preload was varied by transient snaring of the inferior vena cava.
RESULTS: Good quality pressure-volume loops were generated in 13 patients (atrial septal defects, n = 11; double-chambered right ventricle, n = 1; supravalvular aortic stenosis, n = 1; age 0.25 to 14.4 years, weight 3.1 to 46.4 kg). Their mean bypass time was 41 +/- 14 minutes and mean aortic crossclamp time 27 +/- 11 minutes. End-systolic elastance decreased by 40.7% from 0.34 +/- 0.17 to 0.21 +/- 0.15 mm Hg-1.ml-1.kg-1 (p < 0.001). There were no significant changes in the slope of the stroke work-end-diastolic volume relationship, end-diastolic elastance, time constant of isovolumic relaxation, and normalized values of the maxima and minima of the first derivative of developed left ventricular pressure.
CONCLUSION: Load-independent indices of left ventricular function can be derived from left ventricular pressure-volume loops generated by conductance and Mikro-Tip pressure catheters during the perioperative period in infants and children undergoing cardiac operations. Incomplete myocardial protection was demonstrated by a deterioration in systolic function after even short bypass and crossclamp times.
METHODS: Sixteen infants and children with intact ventricular septum undergoing cardiac operations had left ventricular function measured, immediately before and after bypass. Real-time pressure-volume loops were generated by conductance and Mikro-Tip pressure catheters placed in the long-axis via the left ventricular apex, and preload was varied by transient snaring of the inferior vena cava.
RESULTS: Good quality pressure-volume loops were generated in 13 patients (atrial septal defects, n = 11; double-chambered right ventricle, n = 1; supravalvular aortic stenosis, n = 1; age 0.25 to 14.4 years, weight 3.1 to 46.4 kg). Their mean bypass time was 41 +/- 14 minutes and mean aortic crossclamp time 27 +/- 11 minutes. End-systolic elastance decreased by 40.7% from 0.34 +/- 0.17 to 0.21 +/- 0.15 mm Hg-1.ml-1.kg-1 (p < 0.001). There were no significant changes in the slope of the stroke work-end-diastolic volume relationship, end-diastolic elastance, time constant of isovolumic relaxation, and normalized values of the maxima and minima of the first derivative of developed left ventricular pressure.
CONCLUSION: Load-independent indices of left ventricular function can be derived from left ventricular pressure-volume loops generated by conductance and Mikro-Tip pressure catheters during the perioperative period in infants and children undergoing cardiac operations. Incomplete myocardial protection was demonstrated by a deterioration in systolic function after even short bypass and crossclamp times.