Longitudinal Improvements in Radiation Exposure in Cardiac Catheterization for Congenital Heart Disease: A Prospective Multicenter C3PO-QI Study.

Quinn Brian P, Cevallos Priscila, Armstrong Aimee, Balzer David, El-Said Howaida, Foerster Susan, Glatz Andrew C, Goodman Andrea, Goldstein Bryan, Hainstock Michael, Janssen Dana, Kreutzer Jacqueline, Latson Larry, Leahy Ryan, Petit Christopher, Shahanavaz Shabana, Trucco Sara, Whiteside Wendy, Zampi Jeffrey D, Bergersen Lisa

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The C3PO-QI (Congenital Cardiac Catheterization Project on Outcomes - Quality Improvement), a multicenter registry launched in 2015, instituted quality improvement (QI) initiatives to reduce patient radiation exposure. Through regular collaboration, this initiative would allow for harmony among active participants, maximizing efforts and efficiency at achieving radiation best practices. This study sought to report these efforts with a detailed methodology for which institutions can target initiatives, reducing radiation exposure, and increasing patient safety.

METHODS

Data were collected prospectively by 8 C3PO-QI institutions between January 1, 2015 and December 31, 2017. Radiation exposure was measured in dose area product per body weight (dose area product/kg; µGy*m2/kg) and reported by expected radiation exposure categories (REC) and institution for 40 published unique procedure types. Targeted interventions addressing selected strategic domains for radiation reduction were implemented in the pediatric catheterization labs of the C3PO-QI institutions.

RESULTS

The study consisted of 15 257 unique cases. Median exposure (dose area product/kg) was decreased by 30% for all procedures. Dose area product/kg was reduced in all 3 REC, with the greatest improvement observed in REC I (REC I, -37%; REC II, -23%; REC III, -27%). Although the baseline radiation exposures and exact percent decrease varied across all C3PO-QI sites, each institution demonstrated improvements in radiation dose over time. These improvements occurred with the implementation of institution-specific QI interventions accelerated by participation in the C3PO-QI multicenter collaborative.

CONCLUSIONS

Substantial radiation dose reductions can be achieved using targeted QI methodology and interventions. Participation in a multicenter QI collaborative may accelerate improvement across all centers due to enhanced engagement and shared learning between sites.

Для цитирования: Quinn Brian P, Cevallos Priscila, Armstrong Aimee, Balzer David, El-Said Howaida, Foerster Susan, Glatz Andrew C, Goodman Andrea, Goldstein Bryan, Hainstock Michael, Janssen Dana, Kreutzer Jacqueline, Latson Larry, Leahy Ryan, Petit Christopher, Shahanavaz Shabana, Trucco Sara, Whiteside Wendy, Zampi Jeffrey D, Bergersen Lisa. Longitudinal Improvements in Radiation Exposure in Cardiac Catheterization for Congenital Heart Disease: A Prospective Multicenter C3PO-QI Study.. Circulation. Cardiovascular interventions. 2020. DOI: 10.1161/circinterventions.119.008172.