Biometric and structural ocular manifestations of Marfan syndrome.

Gehle Petra, Goergen Barbara, Pilger Daniel, Ruokonen Peter, Robinson Peter N, Salchow Daniel J

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To study biometric and structural ocular manifestations of Marfan syndrome (MFS).

METHODS

Observational, retrospective, comparative cohort study in a tertiary referral center on 285 MFS patients and 267 controls. Structural and biometric ocular characteristic were compared.

RESULTS

MFS eyes were longer (axial length 24.25 ± 1.74 mm versus 23.89 ± 1.31 mm, p < 0.001) and had a flatter cornea than control eyes (mean keratometry 41.78 ± 1.80 diopters (D) versus 43.05 ± 1.51 D, p < 0.001). Corneal astigmatism was greater and the central cornea was thinner in MFS eyes (530.14 ± 41.31 μm versus 547.02 ± 39.18 μm, p < 0.001). MFS eyes were more myopic than control eyes (spherical equivalent -2.16 ± 3.75 D versus -1.17 ± 2.58 D, p < 0.001). Visual acuity was reduced (0.13 ± 0.25 logMAR versus 0.05 ± 0.18 logMAR, p < 0.001) and intraocular pressure was lower in MFS eyes (14.6 ± 3.4 mmHg versus 15.1 ± 3.2 mmHg, p = 0.01). Iris transillumination defects (ITD) were significantly more common in MFS eyes (odds ratio for MFS in the presence of ITD, 3.7). Ectopia lentis (EL) was only present in MFS eyes (33.4%). History of retinal detachment was significantly more common in MFS eyes. Glaucoma was equally common in both groups.

CONCLUSIONS

ITD and EL are most characteristic findings in MFS. ITD and corneal curvature should be studied as diagnostic criteria for MFS. Visual acuity is reduced in MFS. MFS patients need regular eye exams to identify serious ocular complications.

Для цитирования: Gehle Petra, Goergen Barbara, Pilger Daniel, Ruokonen Peter, Robinson Peter N, Salchow Daniel J. Biometric and structural ocular manifestations of Marfan syndrome.. PloS one. 2017. DOI: 10.1371/journal.pone.0183370.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.