DOI 10.1161/circulationaha.105.001438
Homograft valved right ventricle to pulmonary artery conduit as a modification of the Norwood procedure.
Аннотация
BACKGROUND
The use of a right ventricle to pulmonary artery (RV-PA) conduit in the Norwood procedure has been proposed to increase postoperative hemodynamic stability. A valve within the conduit should further decrease RV volume load. We report our clinical experience with this modification.
METHODS AND
RESULTS
From February 2002 through August 2005, we performed 88 consecutive Norwood procedures using RV-PA conduits. We used composite valved conduits made from cryopreserved homograft and polytetrafluoroethylene (PTFE) in 66 cases (54 pulmonary, 12 aortic homografts), other valved conduits in 14, and unvalved PTFE in 8 cases. Hospital survival was 88.6% overall and increased to 93.1% after the initial year. Early interventions were required in 18 patients (16 for cyanosis). Prestage II cardiac catheterization was performed at a mean age of 126 days. Mean Qp/Qs was 1, with mean aortic saturation 71%, mean O2 extraction 24%, and mean right ventricular end-diastolic pressure 9 mm Hg. Patient weight, use of an aortic homograft valve in the conduit, stage I palliation within the first year of our experience, and low O2 extraction and high transpulmonary gradient prestage II were risk factors for overall death. Early interventions were more frequent in aortic valve conduits compared with all other conduits.
CONCLUSIONS
The valved RV-PA conduit was associated with low early mortality after the Norwood procedure. The majority of these patients had normal cardiac output and well-maintained RV function. There may be a higher risk for early conduit interventions and death when aortic valve homografts are used in the RV-PA conduit.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.