MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/09553002.2020.1820611

Медицинская библиотека · International journal of radiation biology · 2020

Estimating partial-body ionizing radiation exposure by automated cytogenetic biodosimetry.

Shirley Ben C, Knoll Joan H M, Moquet Jayne, Ainsbury Elizabeth, Pham Ngoc-Duy, Norton Farrah, Wilkins Ruth C, Rogan Peter K

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Inhomogeneous exposures to ionizing radiation can be detected and quantified with the dicentric chromosome assay (DCA) of metaphase cells. Complete automation of interpretation of the DCA for whole-body irradiation has significantly improved throughput without compromising accuracy, however, low levels of residual false positive dicentric chromosomes (DCs) have confounded its application for partial-body exposure determination.

MATERIALS AND

METHODS

We describe a method of estimating and correcting for false positive DCs in digitally processed images of metaphase cells. Nearly all DCs detected in unirradiated calibration samples are introduced by digital image processing. DC frequencies of irradiated calibration samples and those exposed to unknown radiation levels are corrected subtracting this false positive fraction from each. In partial-body exposures, the fraction of cells exposed, and radiation dose can be quantified after applying this modification of the contaminated Poisson method.

RESULTS

Dose estimates of three partially irradiated samples diverged 0.2-2.5 Gy from physical doses and irradiated cell fractions deviated by 2.3%-15.8% from the known levels. Synthetic partial-body samples comprised of unirradiated and 3 Gy samples from 4 laboratories were correctly discriminated as inhomogeneous by multiple criteria. Root mean squared errors of these dose estimates ranged from 0.52 to 1.14 Gy2 and from 8.1 to 33.3%2 for the fraction of cells irradiated.

CONCLUSIONS

Automated DCA can differentiate whole- from partial-body radiation exposures and provides timely quantification of estimated whole-body equivalent dose.

Для цитирования: Shirley Ben C, Knoll Joan H M, Moquet Jayne, Ainsbury Elizabeth, Pham Ngoc-Duy, Norton Farrah, Wilkins Ruth C, Rogan Peter K. Estimating partial-body ionizing radiation exposure by automated cytogenetic biodosimetry.. International journal of radiation biology. 2020. DOI: 10.1080/09553002.2020.1820611.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.