DOI 10.23736/s2724-5276.19.05487-2
Non-standard approach to infants and children with megacolon: laparotomy and endorectal pull-through for diagnosis and treatment in difficult countries with low resources in a non-profit setting: return to the past Soave's ERPT.
Аннотация
BACKGROUND
Hirschsprung's disease is an important cause of pediatric constipation with high risk of bacterial enterocolitis. Its diagnosis is histological and the suction biopsy is the gold standard. In resource-limited countries, the main diagnostic exam is the contrast enema and mini-invasive surgery lacks. We present the management of a cohort of patients with megacolon in Haiti, a low-resource country.
METHODS
Children with megacolon and fecal impaction admitted at St Damien Children Hospital in Port-Au-Prince in June, August and December 2017 were included. We considered only patients with an evident transition zone on contrast enema who underwent endorectal pull-through (ERPT). Short term complications were recorded.
RESULTS
Twenty children with clinical megacolon were admitted, eleven were included in the study. No suction rectal biopsy and intraoperative histological evaluation were performed. In ten children a Soave ERPT with anastomosis at 5POD was performed, in the other case a Boley primary anastomosis was preferred. One patient complicated with a peritonitis. No major complications were recorded. Colostomy was not considered a good option.
CONCLUSIONS
In developing countries, Soave ERPT with definitive anastomosis after few days could be considered a valid option. Colostomy is suggested only in case of scant general conditions or bad colon appearance.