DOI 10.1016/j.gie.2015.11.031

Медицинская библиотека · Gastrointestinal endoscopy · 2015

Volatile organic compounds in plasma for the diagnosis of esophageal adenocarcinoma: a pilot study.

Bhatt Amit, Parsi Mansour A, Stevens Tyler, Gabbard Scott, Kumaravel Arthi, Jang Sunguk, Grove David, Lopez Rocio, Murthy Sudish, Vargo John J, Dweik Raed

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND AIMS: A noninvasive screening test that can detect esophageal adenocarcinoma (EAC) at an earlier stage could improve the prognosis associated with EAC. The role of plasma volatile organic compounds (VOCs) for the diagnosis of EAC has not been previously studied.

METHODS

Plasma samples were collected from subjects with EAC and GERD before endoscopy. Twenty-two preselected VOCs were analyzed with selected ion flow tube mass spectrometry.

RESULTS

The headspaces from 39 plasma samples (20 EAC, 19 GERD) were analyzed. The levels of 9 VOCs (acetonitrile, acrylonitrile, carbon disulfide, isoprene, 1-heptene, 3-methylhexane, [E]-2-nonene, hydrogen sulfide, and triethylamine) were significantly altered in EAC patients compared with GERD patients. A multivariable logistic regression analysis was performed to build a model for the prediction of EAC. The model identified patients with EAC with an area under the curve of 0.83 (95% confidence interval, 0.67-0.98).

CONCLUSIONS

Plasma VOCs may be useful in diagnosing EAC. Larger studies are needed to confirm our pilot study observations.

Для цитирования: Bhatt Amit, Parsi Mansour A, Stevens Tyler, Gabbard Scott, Kumaravel Arthi, Jang Sunguk, Grove David, Lopez Rocio, Murthy Sudish, Vargo John J, Dweik Raed. Volatile organic compounds in plasma for the diagnosis of esophageal adenocarcinoma: a pilot study.. Gastrointestinal endoscopy. 2015. DOI: 10.1016/j.gie.2015.11.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.