DOI 10.1097/00006982-200007000-00007
External versus internal approach to the removal of metallic intraocular foreign bodies.
Аннотация
OBJECTIVE
To review the management of metallic intraocular foreign bodies (IOFB) at a single institution and to compare the use of internal and external approaches for their removal.
SUBJECTS AND
METHODS
A retrospective review was conducted on 70 eyes from 70 patients who underwent surgical removal of a metallic IOFB with either an internal (vitrectomy followed by forceps or internal magnet use) or external approach (large electromagnet) by seven vitreoretinal surgeons at a single institution between 1973 and 1996. Visual acuity and complications occurring with the two approaches were the main outcome measures studied.
RESULTS
Overall, patients showed significant improvement in visual acuity following surgical intervention (P < 0.001) despite widely varying surgical techniques. When the authors compared patients treated with an external versus an internal approach they found no statistically significant difference with regard to visual outcome and a trend toward a higher rate of postoperative endophthalmitis in the external approach group.
CONCLUSION
Surgical removal of metallic IOFB results in significant visual improvement. The external approach to the removal of magnetic metallic IOFB remains a viable treatment option in select cases.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.