MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.70281

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2026

Zero Fluoroscopy Catheter Ablation of Accessory Pathways and AV Nodal Re-Entry Tachycardia: A Single Institution Study.

Manu Stephen, Briggs Milton, Clark John

СтатьяОбзорПеревод в очереди

Аннотация

BACKGROUND

Minimizing radiation exposure during electrophysiological studies remains an important priority in the catheterization laboratory. With the advancement of imaging and electroanatomic mapping systems, eliminating fluoroscopy from catheter ablation of arrhythmias is becoming more feasible, even for left side procedures requiring transseptal puncture. Nevertheless, there remain concern over the safety and efficacy of a zero-fluoroscopy approach.

OBJECTIVES

The aim of this report was to evaluate the safety and efficacy of a zero-fluoroscopy catheter ablation approach for accessory pathways and atrioventricular nodal-reentrant tachycardia (AVNRT) in a diverse, consecutive patient cohort.

METHODS

This was a retrospective analysis of all patients who underwent radiofrequency ablation or cryoablation of accessory pathways or AVNRT between January 2019 and June 2022 at a single institution. Patient demographics, arrhythmia substrates, ablation energy modalities, and procedural outcomes were evaluated.

RESULTS

There were 166 total ablation procedures performed on 164 unique patients. Fluoroscopy was not used in any of the cases. The mean age was 14.8 years (range 3.1-35.7), of whom 84% were under 18 years of age. Among the 166 procedures performed, 58 involved only typical AVNRT, 1 atypical AVNRT, 99 were accessory pathways, and 8 involved multiple arrhythmia substrates. In all, there were 112 instances of accessory pathways (78 manifest, 34 concealed). Acute procedure success was 99.4%. There were five (5/164, 3%) recurrences after a year of follow-up. There were no complications identified.

CONCLUSION

Zero-fluoroscopy approach to catheter ablation of AVNRT and accessory pathways is safe and effective, further supporting the general adoption of radiation-free techniques in such cases.

Для цитирования: Manu Stephen, Briggs Milton, Clark John. Zero Fluoroscopy Catheter Ablation of Accessory Pathways and AV Nodal Re-Entry Tachycardia: A Single Institution Study.. Pacing and clinical electrophysiology : PACE. 2026. DOI: 10.1111/pace.70281.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.