DOI 10.1186/1749-799x-8-24

Медицинская библиотека · Journal of orthopaedic surgery and research · 2013

Preliminary evaluation of a robotic apparatus for the analysis of passive glenohumeral joint kinematics.

Rosso Claudio, Müller Andreas M, Entezari Vahid, Dow William A, McKenzie Brett, Stanton Stacey K, Li Daniel, Cereatti Andrea, Ramappa Arun J, DeAngelis Joseph P, Nazarian Ara, Della Croce Ugo

Оценочное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The shoulder has the greatest range of motion of any joint in the human body. This is due, in part, to the complex interplay between the glenohumeral (GH) joint and the scapulothoracic (ST) articulation. Currently, our ability to study shoulder kinematics is limited, because existing models isolate the GH joint and rely on manual manipulation to create motion, and have low reproducibility. Similarly, most established techniques track shoulder motion discontinuously with limited accuracy.

METHODS

To overcome these problems, we have designed a novel system in which the shoulder girdle is studied intact, incorporating both GH and ST motions. In this system, highly reproducible trajectories are created using a robotic actuator to control the intact shoulder girdle. High-speed cameras are employed to track retroreflective bone markers continuously.

RESULTS

We evaluated this automated system's capacity to reproducibly capture GH translation in intact and pathologic shoulder conditions. A pair of shoulders (left and right) were tested during forward elevation at baseline, with a winged scapula, and after creation of a full thickness supraspinatus tear.

DISCUSSION: The system detected differences in GH translations as small as 0.5 mm between different conditions. For each, three consecutive trials were performed and demonstrated high reproducibility and high precision.

Для цитирования: Rosso Claudio, Müller Andreas M, Entezari Vahid, Dow William A, McKenzie Brett, Stanton Stacey K, Li Daniel, Cereatti Andrea, Ramappa Arun J, DeAngelis Joseph P, Nazarian Ara, Della Croce Ugo. Preliminary evaluation of a robotic apparatus for the analysis of passive glenohumeral joint kinematics.. Journal of orthopaedic surgery and research. 2013. DOI: 10.1186/1749-799x-8-24.