High-density porous polyethylene wedge implant in correction of enophthalmos and hypoglobus in seeing eyes.

Kashkouli Mohsen Bahmani, Pakdel Farzad, Sasani Leila, Hodjat Parsa, Kaghazkanani Reza, Heirati Abtin

Сравнительное исследованиеКонтролируемое клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

To report the results of post-traumatic enophthalmos/hypophthalmos correction with high-density porous polyethylene wedge implants in seeing eyes.

METHODS

This is an interventional case series of 25 patients (25 eyes) with post-traumatic enophthalmos and hypophthalmos, who underwent orbital reconstruction to correct the enophthalmos and hypophthalmos using Medpor® wedge implant. The aim was an overcorrection of 1 mm in comparison to the other eye, intra-operatively. If needed, trimming of the wedge implant or adding Medpor® sheets were used to achieve the goal. Success was defined as achieving the globe position within 1 mm of the other eye in the last follow-up. Improvement and failure were considered as correction outside the success range of 1 mm and no change in the amount of enophthalmos/hypophthalmos, respectively.

RESULTS

Patients were followed for at least 6 months (mean= 12.66, SD= 12.32). Success, improvement and failure of enophthalmos correction were: 58.3% (14/24), 37.5% (9/24) and 1 (1/24, 4.1%), respectively. Success, improvement and failure of hypophthalmos correction were 73.68% (14/19), 15.78% (3/19) and 5.26% (1/19), respectively. There was no significant difference between the success rate of enophthalmos versus hypophthalmos correction (P= 0.8). Results of 1-month follow up change in enophthalmos and hypophthalmos significantly correlated (r= 0.92, P= 0.000) with the change recorded at last follow up.

CONCLUSIONS

Porous polyethylene wedge implants are useful and safe in correction of enophthalmos and hypoglobus in seeing eyes. Appropriately positioned implant yields no significant difference in correction of enophthalmos versus hypophthalmos.

Для цитирования: Kashkouli Mohsen Bahmani, Pakdel Farzad, Sasani Leila, Hodjat Parsa, Kaghazkanani Reza, Heirati Abtin. High-density porous polyethylene wedge implant in correction of enophthalmos and hypoglobus in seeing eyes.. Orbit (Amsterdam, Netherlands). 2011. DOI: 10.3109/01676830.2011.558971.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.