MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0002-9149(91)90329-j

Медицинская библиотека · The American journal of cardiology · 1991

Pulmonary valve-moderator band distance and association with development of double-chambered right ventricle.

Wong P C, Sanders S P, Jonas R A, Colan S D, Parness I A, Geva T, Van Praagh R, Spevak P J

СтатьяПеревод в очереди

Аннотация

Double-chambered right ventricle (DCRV), a form of right ventricular outflow obstruction that sometimes accompanies a ventricular septal defect (VSD), is associated with superior and rightward displacement of the septal insertion of the moderator band. It was hypothesized that this superior displacement is present and identifiable by echocardiography in patients with a VSD even before right ventricular outflow tract obstruction develops. Eight patients who had a previous echocardiographic study showing a VSD alone were echocardiographically diagnosed as having DCRV. Their initial echocardiographic studies were reviewed, and superior displacement of the moderator band was quantified by measuring the distance between the pulmonary valve and moderator band, normalized to tricuspid anulus diameter. These measurements were compared with those from the initial studies of the following 3 other groups: (1) an age-matched group of 10 patients with no structural heart disease; (2) an age-matched group of 10 patients with a VSD who did not develop DCRV; and (3) a group (not age-matched) of 10 patients with VSD and DCRV in whom subpulmonary obstruction was present on the initial study. The 8 patients who eventually developed subpulmonary obstruction had significant superior displacement of the moderator band at the time of their initial echocardiogram compared with that of the 2 age-matched control groups (p less than 0.01). In contrast, there was no significant difference in moderator band displacement between these patients and the 10 with DCRV who already had right ventricular outflow obstruction at their initial study (p = not significant).(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Wong P C, Sanders S P, Jonas R A, Colan S D, Parness I A, Geva T, Van Praagh R, Spevak P J. Pulmonary valve-moderator band distance and association with development of double-chambered right ventricle.. The American journal of cardiology. 1991. DOI: 10.1016/0002-9149(91)90329-j.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.