MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/wnp.0000000000000615

Медицинская библиотека · Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society · 2020

Lesion-Constrained Electrical Source Imaging: A Novel Approach in Epilepsy Surgery for Tuberous Sclerosis Complex.

Peters Jurriaan M, Hyde Damon E, Chu Catherine J, Boom Merel, Scherrer Benoit, Madsen Joseph R, Stone Scellig S, Ouaalam Hakim, Prabhu Sanjay P, Sahin Mustafa, Warfield Simon K

СтатьяПеревод в очереди

Аннотация

PURPOSE: Electrical source imaging may yield ambiguous results in multilesional epilepsy. The aim of this study was to test the clinical utility of lesion-constrained electrical source imaging in epilepsy surgery in children with tuberous sclerosis complex.

METHODS

Lesion-constrained electrical source imaging is a novel method based on a proposed head model in which the source solution is constrained to lesions. Using a goodness of fit analysis, we rank-ordered individual tubers by their ability to approximate interictal and ictal EEG data. The overlap with the surgical resection cavity was determined qualitatively, and placed findings in the context of epilepsy surgical outcome, and compared with the low-resolution brain electromagnetic tomography solution.

RESULTS

Low-resolution brain electromagnetic tomography predicted the surgical cavity in only one patient with good outcome (true positive) and localized to outside of the cavity in two patients with a good outcome (false negative). In one patient with a poor outcome, the interictal low-resolution brain electromagnetic tomography solution overlapped with the cavity (false positive). Lesion-constrained electrical source imaging of ictal EEG data identified tubers concordant with the resection zone in three patients with a good surgical outcome (true positive) and appropriately discordant in three other patients with a poor outcome (true negative).

CONCLUSIONS

Lesion-constrained electrical source imaging on low-resolution EEG data provides complementary information in the presurgical workup for patients with tuberous sclerosis complex, although further validation is required. In the appropriate clinical context, the yield of source localization on low-resolution EEG data may be increased by reduction of the solution space.

Для цитирования: Peters Jurriaan M, Hyde Damon E, Chu Catherine J, Boom Merel, Scherrer Benoit, Madsen Joseph R, Stone Scellig S, Ouaalam Hakim, Prabhu Sanjay P, Sahin Mustafa, Warfield Simon K. Lesion-Constrained Electrical Source Imaging: A Novel Approach in Epilepsy Surgery for Tuberous Sclerosis Complex.. Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society. 2020. DOI: 10.1097/wnp.0000000000000615.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.