MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.healun.2021.02.011

Медицинская библиотека · The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2021

Resource utilization in children with paracorporeal continuous-flow ventricular assist devices.

Burstein Danielle S, Griffis Heather, Zhang Xuemei, Cantor Ryan S, Dai Dingwei, Shamszad Pirouz, Huang Yuan-Shung, Morales David L S, Hall Matthew, Lin Kimberly Y, O'Connor Matthew J, Zinn Matthew, Edens R Erik, Parrino P Eugene, Kirklin James K, Rossano Joseph W

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Paracorporeal continuous-flow ventricular assist devices (PCF VAD) are increasingly used in pediatrics, yet PCF VAD resource utilization has not been reported to date.

METHODS

Pediatric Interagency Registry for Mechanically Assisted Circulatory Support (PediMACS), a national registry of VADs in children, and Pediatric Health Information System (PHIS), an administrative database of children's hospitals, were merged to assess VAD implants from 19 centers between 2012 and 2016. Resource utilization, including hospital and intensive care unit length of stay (LOS), and costs are analyzed for PCF VAD, durable VAD (DVAD), and combined PCF-DVAD support.

RESULTS

Of 177 children (20% PCF VAD, 14% PCF-DVAD, 66% DVAD), those with PCF VAD or PCF-DVAD are younger (median age 4 [IQR 0-10] years and 3 [IQR 0-9] years, respectively) and more often have congenital heart disease (44%; 28%, respectively) compared to DVAD (11 [IQR 3-17] years; 14% CHD); p < 0.01 for both. Median post-VAD LOS is prolonged ranging from 43 (IQR 15-82) days in PCF VAD to 72 (IQR 55-107) days in PCF-DVAD, with significant hospitalization costs (PCF VAD $450,000 [IQR $210,000-$780,000]; PCF-DVAD $770,000 [IQR $510,000-$1,000,000]). After adjusting for patient-level factors, greater post-VAD hospital costs are associated with LOS, ECMO pre-VAD, greater chronic complex conditions, and major adverse events (p < 0.05 for all). VAD strategy and underlying cardiac disease are not associated with LOS or overall costs, although PCF VAD is associated with higher daily-level costs driven by increased pharmacy, laboratory, imaging, and clinical services costs.

CONCLUSION

Pediatric PCF VAD resource utilization is staggeringly high with costs primarily driven by pre-implantation patient illness, hospital LOS, and clinical care costs.

Для цитирования: Burstein Danielle S, Griffis Heather, Zhang Xuemei, Cantor Ryan S, Dai Dingwei, Shamszad Pirouz, Huang Yuan-Shung, Morales David L S, Hall Matthew, Lin Kimberly Y, O'Connor Matthew J, Zinn Matthew, Edens R Erik, Parrino P Eugene, Kirklin James K, Rossano Joseph W. Resource utilization in children with paracorporeal continuous-flow ventricular assist devices.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2021. DOI: 10.1016/j.healun.2021.02.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.