Optic nerve sheath diameter as a non-invasive tool to detect clinically relevant raised intracranial pressure in children: an observational analytical study.

Bansal Anmol, Tiwari Lokesh Kumar, Kumar Pradeep, Jain Raina

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Raised intracranial pressure (ICP) contributes to approximately 20% of the admissions in the paediatric intensive care unit (PICU) in our setting. Timely identification and treatment of raised ICP is important to prevent brain herniation and death in such cases. The objective of this study was to examine the role of optic nerve sheath diameter (ONSD) in detecting clinically relevant raised ICP in children.

METHODS

A hospital-based observational analytical study in a PICU of a tertiary care institute in India on children aged 2-14 years. ONSD was measured in all children on three time points that is, day 1, day 2 and between day 4 and 7 of admission. ONSD values were compared between children with and without clinical signs of raised ICP.

RESULTS

Out of 137 paediatric patients recruited, 34 had signs of raised ICP. Mean ONSD on day 1 was higher in children with signs of raised ICP (4.99±0.57 vs 4.06±0.40; p<0.01). Mean ONSD on day 2 also was higher in raised ICP patients (4.94±0.55 vs 4.04±0.40; p<0.01). The third reading between days 4 and 7 of admission was less than the first 2 values but still higher in raised ICP patients (4.48±1.26 vs 3.99±0.57; p<0.001). The cut-off ONSD value for detecting raised ICP was 4.46 mm on the ROC curve with an area under curve 0.906 (95% CI 0.844 to 0.968), 85.3% sensitivity and 86.4% specificity. There was no difference in ONSD between the right and the left eyes at any time point irrespective of signs of raised ICP.

CONCLUSION

We found that measurement of ONSD by transorbital ultrasound was able to detect clinically relevant raised ICP with an excellent discriminatory performance at the cut-off value of 4.46 mm.

Для цитирования: Bansal Anmol, Tiwari Lokesh Kumar, Kumar Pradeep, Jain Raina. Optic nerve sheath diameter as a non-invasive tool to detect clinically relevant raised intracranial pressure in children: an observational analytical study.. BMJ paediatrics open. 2024. DOI: 10.1136/bmjpo-2023-002353.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.