MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2020.07.043

Медицинская библиотека · Injury · 2020

Tourniquet use for extremity fractures has no adverse effect on number of ventilator days for patients who are treated with reamed femoral or tibial shaft nails.

Coale Max, Costales Timothy, Zerhusen Timothy, Baker Mitchell, Pollak Andrew N, Jarman Molly P, Castillo Renan C, O'Toole Robert V

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Concern exists regarding the pulmonary effects of using tourniquets for secondary extremity fractures in patients also undergoing intramedullary nail (IMN) fixation of femoral or tibial shaft fractures. Our hypothesis was that tourniquet use would be associated with increased ventilator days.

METHODS

At a Level I trauma center, we conducted a retrospective review of 1966 patients with 2018 fractures (1070 femoral shaft and 948 tibial shaft) treated with IMN from December 2006 to September 2014. Medical record review and bivariate and multiple variable regression analyses were conducted, and the main outcome measurement was number of ventilator days.

RESULTS

No statistically significant negative association was found between use of a tourniquet and number of ventilator days in the femoral or tibial fracture group. Use of tourniquets in the upper extremities showed a statistically significant decrease in amount of ventilator days in the femoral group (-2.2 days, p = 0.003) but no association in the tibial group (1.1 days, p = 0.36). Use of tourniquets concurrently in both upper and lower extremities of both femoral and tibial groups also had a protective effect (-6.8 days, p < 0.001 and -2.3 days, p = 0.009, respectively). Stratified and sensitivity analyses (to account for effects of mortality and missing data) showed consistently similar results.

CONCLUSION

Tourniquet use for secondary extremity fractures, in patients also undergoing IMN fixation for femoral or tibial shaft fractures, was not associated with an increased number of ventilator days. A potential protective effect of tourniquet use was shown in patients with upper extremity fractures and in those with both upper and lower extremity fractures.

LEVEL OF EVIDENCE: Therapeutic Level III (Retrospective cohort study).

Для цитирования: Coale Max, Costales Timothy, Zerhusen Timothy, Baker Mitchell, Pollak Andrew N, Jarman Molly P, Castillo Renan C, O'Toole Robert V. Tourniquet use for extremity fractures has no adverse effect on number of ventilator days for patients who are treated with reamed femoral or tibial shaft nails.. Injury. 2020. DOI: 10.1016/j.injury.2020.07.043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.