MedElevator Войти в исследования
← Поиск публикаций

DOI 10.17116/otorino20238805127

Медицинская библиотека · Vestnik otorinolaringologii · 2023

[Diagnostic efficiency of transcutaneous ultrasound scanning and Dopplerography in laryngeal pathology].

Subbotina M V

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the efficiency and the place of grey scale ultrasound and color Doppler sonography of the larynx in the diagnosis of laryngeal pathology.

MATERIAL AND

METHODS

A prospective blind cohort examination in B-mode laryngeal ultrasound (LUS) and color Doppler imaging (CDI) with linear scanning transducer 7-15 MHz was performed in 120 patients aged from 6 months to 52 years (average age 7.6±5.8 years, Me 6 year) and in 40 patients without laryngeal pathology (average age 7.0±5.0 years). The patients presented with complaints of voice and/or stridor. The diagnosis was verified by followed laryngoscopy.

RESULTS

Laryngeal papillomas, hemangiomas, scarring and vocal fold's nodules were identified as hyperechoic formations. Color Doppler sonography made it possible to visualize them better: small formations were highlighted in color and the space around the large ones was colored. There were paradoxical movements of the hyperechoic arytenoid cartilages during inspiration to the anterior commissure in patients with laryngomalacia. Color Doppler ultrasonography revealed changes during phonation in patients with functional dysphonia. The sensitivity and specificity of LUS were 58% (95% CI 48-66) and 98% (95% CI 87-99) compared with laryngoscopy in the detection of laryngeal pathology, but laryngeal CDI - 81% (95% CI 72-87) and 98% (95% CI 87-99) respectively.

CONCLUSION

Ultrasound of the larynx in B-mode has a diagnostic efficiency of 67.5%, and in CDI mode - 85% for ruling in laryngeal pathologies compared to laryngoscopy. So, this method is a modern affordable, non-invasive and informative diagnostic tool for the detection of laryngeal diseases, especially in those cases, when it is impossible to carry out a laryngoscopy.

Для цитирования: Subbotina M V. [Diagnostic efficiency of transcutaneous ultrasound scanning and Dopplerography in laryngeal pathology].. Vestnik otorinolaringologii. 2023. DOI: 10.17116/otorino20238805127.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.