MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/uog.967

Медицинская библиотека · Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2004

Quantitative three-dimensional sonographic assessment of pelvic blood after transvaginal ultrasound-guided oocyte aspiration: factors predicting risk.

Shalev J, Davidi O, Fisch B

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the fluid volume in the pelvis immediately and 3-5 days after transvaginal ultrasound-guided oocyte aspiration (TOAS) and to identify predictive factors for intraperitoneal bleeding.

METHODS

This was a prospective study of 83 infertile women undergoing controlled ovarian hyperstimulation followed by TOAS and embryo transfer (ET). Pelvic blood volume was measured by three-dimensional (3D) ultrasound examination 3-5 h after TOAS (post-TOAS), and prior to ET (2-3 days after TOAS; pre-ET). Pelvic blood volume was then correlated with the following procedure-related variables: day of hCG administration: number and diameter of ovarian follicles, endometrial thickness, serum estradiol levels; day of TOAS: number of retrieved oocytes, patient's perceived pain (Likert scale), duration of TOAS, diameters (using two-dimensional (2D) ultrasound) and 3D volume of pelvic fluid; day of ET: 2D diameters and 3D volume of pelvic fluid, perceived pain; pregnancy rate.

RESULTS

The mean +/- SD volume of blood measured by 3D ultrasound after TOAS and before ET was 12.94 +/- 16.88 (range, 0-98.00) mL and 19.13 +/- 17.84 (range, 0-70.20) mL, respectively. Blood volume in the pelvis correlated most strongly with number of oocytes retrieved (post-TOAS: P < 0.01; pre-ET: P < 0.05), followed by pain level (post-TOAS: P < 0.01), number of follicles (post-TOAS: P < 0.05) and endometrial thickness (post-TOAS: P < 0.05). When all study variables were held constant, the number of oocytes and serum estradiol level proved to be significant predictors of the amount of fluid in the pelvis (post-TOAS/pre-ET: P < 0.01). If 2D ultrasound was used, the best predictor of fluid volume after TOAS was the width of the fluid scanned in the pelvis (P < 0.001).

CONCLUSIONS

The amount of blood in the pelvis following TOAS in the present series was within acceptable clinical limits. The number of retrieved oocytes and pain after TOAS were found to be indicators of patients at risk of excessive bleeding. These findings have important implications for the improvement of postprocedural care.

Для цитирования: Shalev J, Davidi O, Fisch B. Quantitative three-dimensional sonographic assessment of pelvic blood after transvaginal ultrasound-guided oocyte aspiration: factors predicting risk.. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2004. DOI: 10.1002/uog.967.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.