MedElevator Войти в исследования
← Поиск публикаций

DOI 10.33963/kp.a2022.0173

Медицинская библиотека · Kardiologia polska · 2022

Prognostic value of computed tomography derived measurements of pulmonary artery diameter for long-term outcomes after transcatheter aortic valve replacement.

Kalińczuk Łukasz, Chmielak Zbigniew, Dąbrowski Maciej, Mazurkiewicz Marcin, Stokłosa Patrycjusz, Skotarczak Wiktor, Mintz Gary S, Wolny Rafał, Tyczyński Paweł, Konka Marek, Michałowska Anna, Kowalik Ilona, Demkow Marcin, Michałowska Ilona, Witkowski Adam

СтатьяПеревод в очереди

Аннотация

BACKGROUND

An increase in pulmonary artery diameter (PAD) on multi-detector computed tomography (MDCT) may indicate pulmonary hypertension. We assessed the prognostic value of MDCT-derived measurements of PAD on outcomes after successful transcatheter aortic valve replacement (TAVR).

METHODS

Consecutive patients treated with TAVR from February 2013 to October 2017, with a 68.8% rate of new generation valves, underwent pre-interventional MDCT with measurements of PAD (in the widest short-axis within 3 cm of the bifurcation) and ascending aortic diameter (AoD; at the level of the PAD). The PAD/AoD ratio was calculated. Patients with high-density lipoprotein cholesterol levels ≤46 mg/dl and C-reactive protein levels ≥0.20 mg/dl at baseline were identified as the frail group. One-year mortality was established for all subjects.

RESULTS

Among studied 266 patients (median age, 82.0 years; 63.5% women) those who died at 1 year (n = 34; 12.8%) had larger PAD and PAD/AoD (28.9 [5.0] vs. 26.5 [4.6] mm and 0.81 [0.13] vs. 0.76 [0.13] mm vs. the rest of the studied subjects; P = 0.005 and P = 0.02, respectively) but similar AoD. The cutoff value for the PAD to predict 1-year mortality was 29.3 mm (sensitivity, 50%; specificity, 77%; area under the curve, 0.65). Patients with PAD >29.3 mm (n = 72; 27%) had higher 1-year mortality (23.6% vs. 8.8%, log-rank P = 0.001). Baseline characteristics associated with PAD29.3 mm were a bigger body mass index, more frequent diabetes mellitus, more prior stroke/transient ischemic attacks and atrial fibrillation, and lower baseline maximal aortic valve gradient with higher pulmonary artery systolic pressure (PASP). PAD >29.3 mm and frailty, but not baseline PASP, remained predictive of 1-year mortality in the multivariable model (hazard ratio [HR], 2.221; 95%CI, 1.038-4.753; P = 0.04 and HR, 2.801; 95% CI, 1.328-5.910; P = 0.007, respectively).

CONCLUSION

PAD >29.3 mm on baseline MDCT is associated with higher 1-year mortality after TAVR, independently of echocardiographic measures of PH and frailty.

Для цитирования: Kalińczuk Łukasz, Chmielak Zbigniew, Dąbrowski Maciej, Mazurkiewicz Marcin, Stokłosa Patrycjusz, Skotarczak Wiktor, Mintz Gary S, Wolny Rafał, Tyczyński Paweł, Konka Marek, Michałowska Anna, Kowalik Ilona, Demkow Marcin, Michałowska Ilona, Witkowski Adam. Prognostic value of computed tomography derived measurements of pulmonary artery diameter for long-term outcomes after transcatheter aortic valve replacement.. Kardiologia polska. 2022. DOI: 10.33963/kp.a2022.0173.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.