MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12984-015-0004-x

Медицинская библиотека · Journal of neuroengineering and rehabilitation · 2015

Validation of an activity monitor for children who are partly or completely wheelchair-dependent.

Nooijen Carla Fj, de Groot Janke F, Stam Henk J, van den Berg-Emons Rita Jg, Bussmann Hans Bj, Fit for the Future Consortium

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Children who are wheelchair-dependent are at risk for developing unfavorable physical behavior; therefore, assessment, monitoring and efforts to improve physical behavior should start early in life. VitaMove is an accelerometer-based activity monitor and can be used to detect and distinguish different categories of physical behavior, including activities performed in a wheelchair and activities using the legs. The purpose of this study was to assess the validity of the VitaMove activity monitor to quantify physical behavior in children who are partly or completely wheelchair-dependent.

METHODS

Twelve children with spina bifida (SB) or cerebral palsy (CP) (mean age, 14 ± 4 years) performed a series of wheelchair activities (wheelchair protocol) and, if possible, activities using their legs (n = 5, leg protocol). Activities were performed at their own home or school. In children who were completely wheelchair-dependent, VitaMove monitoring consisted of one accelerometer-based recorder attached to the sternum and one to each wrist. For children who were partly ambulatory, an additional recorder was attached to each thigh. Using video-recordings as a reference, primary the total duration of active behavior, including wheeled activity and leg activity, and secondary agreement, sensitivity and specificity scores were determined.

RESULTS

Detection of active behaviour with the VitaMove activity monitor showed absolute percentage errors of 6% for the wheelchair protocol and 10% for the leg protocol. For the wheelchair protocol, the mean agreement was 84%, sensitivity was 80% and specificity was 85%. For the leg protocol, the mean agreement was 83%, sensitivity was 78% and specificity was 90%. Validity scores were lower in severely affected children with CP.

CONCLUSIONS

The VitaMove activity monitor is a valid device to quantify physical behavior in children who are partly or completely wheelchair-dependent, except for severely affected children and for bicycling.

Для цитирования: Nooijen Carla Fj, de Groot Janke F, Stam Henk J, van den Berg-Emons Rita Jg, Bussmann Hans Bj, Fit for the Future Consortium. Validation of an activity monitor for children who are partly or completely wheelchair-dependent.. Journal of neuroengineering and rehabilitation. 2015. DOI: 10.1186/s12984-015-0004-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.