MedElevator Войти в исследования
← Поиск публикаций
European radiology · 2019

Prediction of pulmonary pressure after Glenn shunts by computed tomography-based machine learning models.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Huang Lei, Li Jiahua, Huang Meiping, Zhuang Jian, Yuan Haiyun, Jia Qianjun, Zeng Dewen, Que Lifeng, Xi Yue, Lin Jijin, Dong Yuhao

Аннотация

OBJECTIVES: This study aimed to develop non-invasive machine learning classifiers for predicting post-Glenn shunt patients with low and high risks of a mean pulmonary arterial pressure (mPAP) > 15 mmHg based on preoperative cardiac computed tomography (CT).

METHODS: This retrospective study included 96 patients with functional single ventricle who underwent a bidirectional Glenn procedure between November 1, 2009, and July, 31, 2017. All patients underwent post-procedure CT, followed by cardiac catheterization. Overall, 23 morphologic parameters were manually extracted from cardiac CT images for each patient. The Mann-Whitney U or chi-square test was applied to select the most significant predictors. Six machine learning algorithms including logistic regression, Naive Bayes, random forest (RF), linear discriminant analysis, support vector machine, and K-nearest neighbor were used for modeling. These algorithms were independently trained on 100 train-validation random splits with a 3:1 ratio. Their average performance was evaluated by area under the curve (AUC), accuracy, sensitivity, and specificity.

RESULTS: Seven CT morphologic parameters were selected for modeling. RF obtained the best performance, with mean AUC of 0.840 (confidence interval [CI] 0.832-0.850) and 0.787 (95% CI 0.780-0.794); sensitivity of 0.815 (95% CI 0.797-0.833) and 0.778 (95% CI 0.767-0.788), specificity of 0.766 (95% CI 0.748-0.785) and 0.746 (95% CI 0.735-0.757); and accuracy of 0.782 (95% CI 0.771-0.793) and 0.756 (95% CI 0.748-0.764) in the training and validation cohorts, respectively.

CONCLUSIONS: The CT-based RF model demonstrates a good performance in the prediction of mPAP, which may reduce the need for right heart catheterization in post-Glenn shunt patients with suspected mPAP > 15 mmHg.

KEY POINTS: • Twenty-three candidate descriptors were manually extracted from cardiac computed tomography images, and seven of them were selected for subsequent modeling. • The random forest model presents the best predictive performance for pulmonary pressure among all methods. • The computed tomography-based machine learning model could predict post-Glenn shunt pulmonary pressure non-invasively.

Предметные рубрики MeSH