DOI 10.1016/j.jpeds.2019.05.048
Prospective Assessment of Ultrasound Shear Wave Elastography for Discriminating Biliary Atresia from other Causes of Neonatal Cholestasis.
Аннотация
OBJECTIVE
To prospectively assess the diagnostic performance of ultrasound shear wave elastography (SWE) and hepatobiliary laboratory biomarkers for discriminating biliary atresia from other causes of neonatal cholestasis.
STUDY
DESIGN
Forty-one patients <3 months of age with neonatal cholestasis (direct bilirubin >2 mg/dL) and possible biliary atresia were prospectively enrolled. Both 2-dimensional (2D) and point ultrasound SWE were performed prior to knowing the final diagnosis. Median 2D (8) and point (10) shear wave speed measurements were calculated for each subject and used for analyses. The Mann-Whitney U test was used to compare shear wave speed and laboratory measurements between patients with and without biliary atresia. Receiver operating characteristic curve analyses and multivariable logistic regression were used to evaluate diagnostic performance.
RESULTS
Thirteen subjects (31.7%) were diagnosed with biliary atresia, and 28 subjects (68.3%) were diagnosed with other causes of neonatal cholestasis. Median age at the time of ultrasound SWE was 37 days. Median 2D (2.08 vs 1.49 m/s, P = .0001) and point (1.95 vs 1.21 m/s, P = .0014) ultrasound SWE measurements were significantly different between subjects with and without biliary atresia. Using a cut-off value of >1.84 m/s, 2D ultrasound SWE had a sensitivity = 92.3%, specificity = 78.6%, and area under the receiver operating characteristic curve (AuROC) of 0.89 (P < .0001). Using a cut-off value of >320 (U/L), gamma-glutamyl transferase (GGT) had a sensitivity = 100.0%, specificity = 77.8%, and AuROC of 0.85 (P < .0001). Multivariable logistic regression demonstrated an AuROC of 0.93 (P < .0001), with 2 significant covariates (2D ultrasound SWE [OR = 23.06, P = .01]; GGT [OR = 1.003, P = .036]).
CONCLUSIONS
Ultrasound SWE and GGT can help discriminate biliary atresia from other causes of neonatal cholestasis.