MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-014-3450-0

Медицинская библиотека · European radiology · 2014

Morphologic assessment of thoracic deformities for the preoperative evaluation of pectus excavatum by magnetic resonance imaging.

Lollert A, Funk J, Tietze N, Turial S, Laudemann K, Düber C, Staatz G

Оценочное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To assess whether MRI is a suitable modality for the preoperative assessment and quantification of pectus excavatum.

METHODS

A total of 69 patients (57 male, 12 female; median age 15 years, range 5-35 years) with pectus excavatum were evaluated preoperatively using standardized MRI sequences on 1.5- and 3-Tesla systems (T2-HASTE/inspiration and expiration, T1-VIBE, T2-TRUFI free-breathing, T2-BLADE). The MR sequences were analysed for quality semiquantitatively. The Haller index, correction index, sternal rotation angle and asymmetry index were assessed; correlations between these indices and changes in inspiration and expiration were evaluated.

RESULTS

T2-HASTE was the best sequence to assess pectus excavatum morphology, with a higher quality at 3 T than at 1.5 T. All indices could be assessed in every patient. A total of 37 patients had a symmetric deformity, 32 patients an asymmetric deformity. The Haller index correlated significantly (p < 0.001) with the correction index, both becoming higher in expiration. The asymmetry index correlated with the sternal rotation angle (p < 0.001) and did not change significantly in expiration (p = 0.28).

CONCLUSIONS

Thoracic MRI is suitable for the preoperative evaluation of patients with pectus excavatum. An exact morphologic assessment is possible without radiation exposure as well as the determination of several indices to quantify the deformities.

Для цитирования: Lollert A, Funk J, Tietze N, Turial S, Laudemann K, Düber C, Staatz G. Morphologic assessment of thoracic deformities for the preoperative evaluation of pectus excavatum by magnetic resonance imaging.. European radiology. 2014. DOI: 10.1007/s00330-014-3450-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.