Di Filippo Sylvie, Semiond Bertrand, Roriz Ricardo, Sassolas Francois, Raboisson Marie José, Bozio André
Аннотация
BACKGROUND: Coronary vasculopathy is the main cause of cardiac graft failure. Because yearly coronary angiography is invasive in children, a non-invasive method for detecting graft vasculopathy is needed. The aim of this study was to test dobutamine-stress echocardiography in a pediatric population to determine its feasibility, safety and reliability in the detection of graft coronary artery disease.
METHODS: Eighteen patients, aged 2 days to 16.8 years at transplantation (mean 8.4 years), underwent 44 dobutamine-stress echocardiography (DSE) exams, at a follow-up of 1.1 to 11.8 years (mean 5.1 years). Selective coronary angiography was performed for comparison. Echocardiographic recordings were obtained in 4 standard views of the left ventricle and measurements carried out within the frames of a 16-segment model. Segmental scores of contractility were obtained for each segment and a total segmental contractility index was calculated at each stage.
RESULTS: All patients reached the maximum dose stage. Maximum heart rate was 57% to 90% of predicted maximum. Maximum systolic blood pressure reached 190 mmHg. Segmental scores were normal in 37 and abnormal in 7 cases. Echographic results were concordant with angiography in 82% and discordant in 18% of the cases (4 negative DSEs with minor angiographic lesions, 2 positive DSEs with normal angiography), but there was no significant angiographic lesion with normal DSE.
CONCLUSIONS: DSE is a safe and highly feasible non-invasive technique in transplanted children. A normal DSE study successfully predicts the absence of significant coronary artery disease in the post-transplant population.
METHODS: Eighteen patients, aged 2 days to 16.8 years at transplantation (mean 8.4 years), underwent 44 dobutamine-stress echocardiography (DSE) exams, at a follow-up of 1.1 to 11.8 years (mean 5.1 years). Selective coronary angiography was performed for comparison. Echocardiographic recordings were obtained in 4 standard views of the left ventricle and measurements carried out within the frames of a 16-segment model. Segmental scores of contractility were obtained for each segment and a total segmental contractility index was calculated at each stage.
RESULTS: All patients reached the maximum dose stage. Maximum heart rate was 57% to 90% of predicted maximum. Maximum systolic blood pressure reached 190 mmHg. Segmental scores were normal in 37 and abnormal in 7 cases. Echographic results were concordant with angiography in 82% and discordant in 18% of the cases (4 negative DSEs with minor angiographic lesions, 2 positive DSEs with normal angiography), but there was no significant angiographic lesion with normal DSE.
CONCLUSIONS: DSE is a safe and highly feasible non-invasive technique in transplanted children. A normal DSE study successfully predicts the absence of significant coronary artery disease in the post-transplant population.