MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2015.05.018

Медицинская библиотека · JACC. Cardiovascular interventions · 2015

Stent Repair for Complex Coarctation of Aorta.

Suárez de Lezo José, Romero Miguel, Pan Manuel, Suárez de Lezo Javier, Segura José, Ojeda Soledad, Pavlovic Djordje, Mazuelos Francisco, López Aguilera José, Espejo Perez Simona

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study sought to determine whether several anatomic or evolving characteristics of the coarctation may create challenging conditions for treatment.

BACKGROUND

Stent repair of coarctation of aorta is an alternative to surgical correction.

METHODS

We analyzed our 21-year experience in the percutaneous treatment of complex coarctation of aorta. Adverse conditions for treatment were as follow: 1) complete interruption of the aortic arch (n = 11); 2) associated aneurysm (n = 18); 3) complex stenosis (n = 30); and 4) the need for re-expansion and/or restenting (n = 21). Twenty patients (33%) belonged to more than 1 group. Ten interruptions were type A and 1 was type B. The mean length of the interrupted aorta was 9 ± 11 mm. The associated aneurysms were native in 8 patients and after previous intervention in 10 patients. Aneurysm shapes were fusiform in 8 patients and saccular in 10. The following characteristics defined complex stenosis as long diffuse stenosis, very tortuous coarctation, or stenosis involving a main branch or an unusual location. Patients previously stented at an early age, required re-expansion and/or restenting after reaching 16 ± 5 years of age.

RESULTS

Two patients had died by 1-month follow-up. The remaining 58 patients did well and were followed-up for a mean period of 10 ± 6 years. Late adverse events occurred in 3 patients (5%). All remaining patients are symptom-free, with normal baseline blood pressure. Imaging techniques revealed good patency at follow-up without associated aneurysm or restenosis. The actuarial survival free probability of all complex patients at 15 years was 92%.

CONCLUSIONS

Stent repair of complex coarctation of aorta is feasible and safe. Initial results are maintained at later follow-up.

Для цитирования: Suárez de Lezo José, Romero Miguel, Pan Manuel, Suárez de Lezo Javier, Segura José, Ojeda Soledad, Pavlovic Djordje, Mazuelos Francisco, López Aguilera José, Espejo Perez Simona. Stent Repair for Complex Coarctation of Aorta.. JACC. Cardiovascular interventions. 2015. DOI: 10.1016/j.jcin.2015.05.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.