m+Medelevator.RU
← Поиск публикаций
American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics · 2025

Automated assessment of nasal septum deviation using cone-beam computed tomography images based on artificial intelligence: Development and multicenter validation.

СтатьяВалидационное исследованиеМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhai Qianglan, Cui Mengjuan, Fu Yijiao, Huang Xingtai, Wang Zhengliang, Wu Qingwen, Cong Ning, Liu Chao

Аннотация

INTRODUCTION: Nasal septum deviation (NSD) is one of the contributing factors to impaired nasal function and dentofacial developmental abnormalities. Although cone-beam computed tomography (CBCT) is clinically valuable for NSD diagnosis, manual interpretation remains labor-intensive and expertise-dependent.

METHODS: Our study included 330 CBCT scans diagnosed with either NSD or non-NSD to develop an automated 2-stage artificial intelligence (AI) framework integrating real-time detection and classification for NSD screening. In the first stage, the YOLOv11 (You Only Look Once) object detection algorithm was employed to detect the region of interest containing the nasal septum. In the second stage, 3 convolutional neural network architectures, ResNet, EfficientNet, and MobileNet, were evaluated for classifying CBCT images into NSD and normal categories.

RESULTS: Among the YOLOv11 variants, YOLOv11n demonstrated superior performance with a precision of 0.996, a recall of 1.000, an mAP50 of 0.995, and an mAP50-95 of 0.873. For the classification task, Mobile_small emerged as the top-performing model, achieving an area under the curve of 0.817, an area under the precision-recall curve of 0.845, and an accuracy of 0.749. An AI-assisted diagnostic tool was developed based on YOLOv11n and MobileNet models and validated on 50 internal and 50 external CBCT scans. With AI assistance, orthodontists' diagnostic accuracy increased by 20.12% and 21.49%, respectively, whereas average diagnosis time decreased by 23.75 seconds, improving efficiency by 53.92%.

CONCLUSIONS: The proposed system enables rapid NSD screening with diagnostic-level accuracy, demonstrating the viability of lightweight AI models for clinical CBCT analysis. AI-assisted diagnosis improves orthodontists' accuracy and time efficiency in identifying NSD.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты