m+Medelevator.RU
← Поиск публикаций
The journal of hand surgery Asian-Pacific volume · 2018

Computer-Assisted Three-Dimensional Corrective Osteotomy for Malunited Fractures of the Distal Radius Using Prefabricated Bone Graft Substitute.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shintani Kosuke, Kazuki Kenichi, Yoneda Masahiro, Uemura Takuya, Okada Mitsuhiro, Takamatsu Kiyohito, Nakamura Hiroaki

Аннотация

BACKGROUND: Three-dimensional computed tomography (3D-CT) imaging has enabled more accurate preoperative planning. The purpose of this study was to investigate the results of a novel, computer-assisted, 3D corrective osteotomy using prefabricated bone graft substitute to treat malunited fractures of the distal radius.

METHODS: We investigated 19 patients who underwent the computer-assisted 3D corrective osteotomy for a malunited fracture of the distal radius after the operation was stimulated with CT data. A prefabricated bone graft substitute corresponding to the patient's bone defect was implanted and internal fixation was performed using a plate and screws. We compared postoperative radiographic parameters of the patient's operated side with their sound side and analyzed clinical outcomes using Mayo wrist score.

RESULTS: All patients achieved bone union on X-ray imaging at final follow-up. The mean differences of palmar tilt, radial inclination and ulnar variance between the operation side and the sound side were 4.3°, 2.3° and 1.2 mm, respectively. The Mayo wrist score was fair in 4 patients and poor in 15 patients before surgery. At the final follow-up after surgery, the scores improved to excellent in 3 patients, good in 11 patients and fair in 5 patients. There were two patients with correction loss at the final follow-up, but no patient complained of hand joint pain.

CONCLUSIONS: We believe that computer-assisted 3D corrective osteotomy using prefabricated bone graft substitute achieved good results because it worked as a guide to the accurate angle.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты