Potential Factors Affected Safety and Efficacy of Transcatheter Plug Closure for Pediatric Hemoptysis with Anomalous Bronchial Arteries.

Kuang Hong-Yu, Li Qiang, Xiang Ping, Feng Chuan, Yi Qi-Jian, Lu Tie-Wei

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the safety and efficacy of interventional care in pediatric hemoptysis for anomalous bronchial arteries (BAs) and to identify the potential factors resulting in hemoptysis recurrence.

METHODS

20 children complained of hemoptysis were diagnosed with anomalous BAs. All patients received transcatheter plug occlusion in Department of Cardiology, Children's Hospital of Chongqing Medical University. The safety and efficacy were evaluated according to clinical symptoms and images monitoring of enrolled subjects grouped as recurrence group and nonrecurrence group. The potential factors causing hemoptysis recurrence were reviewed and summarized.

RESULTS

No deaths were recorded in a follow-up. Otherwise, hemoptysis recurrence was found in 8 subjects for 14 times, accounting for about 40%. Compared with nonrecurrence group, it indicated a statistical significance in hemoglobin levels (P=0.049), mycoplasma pneumonia particle assays (MP-PA) titers (P=0.030), and number of anomalous BAs (P=0.020). Meanwhile, 50% recurrent scenarios were associated with a respiratory infection by microbiological assessment before transcatheter plug occlusion. The repeat occlusion was applied for unclosed BAs leading to visual recurrent hemoptysis, the average interval time of which was 5.4 ± 3.6 mon.

CONCLUSION

The data from this retrospective study have shown that transcatheter plug occlusion is a relatively safe procedure with a low mortality. The number of abnormal BAs has been identified as a highly significant predictor of recurrence, and the role of MP and other potential factors should be verified in a multicenter, larger sample size, and randomized controlled trial.

Для цитирования: Kuang Hong-Yu, Li Qiang, Xiang Ping, Feng Chuan, Yi Qi-Jian, Lu Tie-Wei. Potential Factors Affected Safety and Efficacy of Transcatheter Plug Closure for Pediatric Hemoptysis with Anomalous Bronchial Arteries.. Journal of interventional cardiology. 2019. DOI: 10.1155/2019/5408618.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.