MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lsm.10113

Медицинская библиотека · Lasers in surgery and medicine · 2003

Experimental photodynamic therapy for malignant pleural mesothelioma with pegylated mTHPC.

Krueger Thorsten, Altermatt Hans J, Mettler Daniel, Scholl Beatrix, Magnusson Lennart, Ris Hans-Beat

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Experimental assessment of photodynamic therapy (PDT) for malignant pleural mesothelioma using a polyethylene glycol conjugate of meta-tetrahydroxyphenylchlorin (PEG-mTHPC).

STUDY DESIGN/MATERIALS AND

METHODS

(a) PDT was tested on H-meso-1 xenografts (652 nm laser light; fluence 10 J/cm(2); 0.93, 9.3, or 27.8 mg/kg of PEG-mTHPC; drug-light intervals 3-8 days). (b) Intraoperative PDT with similar treatment conditions was performed in the chest cavity of minipigs (n = 18) following extrapleural pneumonectomy (EPP) using an optical integrating balloon device combined with in situ light dosimetry.

RESULTS

(a) PDT using PEG-mTHPC resulted in larger extent of tumor necrosis than in untreated tumors (P < or = 0.01) without causing damage to normal tissue. (b) Intraoperative PDT following EPP was well tolerated in 17 of 18 animals. Mean fluence and fluence rates measured at four sites of the chest cavity ranged from 10.2 +/- 0.2 to 13.2 +/- 2.3 J/cm(2) and 5.5 +/- 1.2 to 7.9 +/- 1.7 mW/cm(2) (mean +/- SD). Histology 3 months after light delivery revealed no PDT related tissue injury in all but one animal.

CONCLUSIONS

PEG-mTHPC mediated PDT showed selective destruction of mesothelioma xenografts without causing damage to intrathoracic organs in pigs at similar treatment conditions. The light delivery system afforded regular light distribution to different parts of the chest cavity.

Для цитирования: Krueger Thorsten, Altermatt Hans J, Mettler Daniel, Scholl Beatrix, Magnusson Lennart, Ris Hans-Beat. Experimental photodynamic therapy for malignant pleural mesothelioma with pegylated mTHPC.. Lasers in surgery and medicine. 2003. DOI: 10.1002/lsm.10113.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.