m+Medelevator.RU
← Поиск публикаций
Journal of prosthodontics : official journal of the American College of Prosthodontists · 2021

Effect of Staining Solutions on Color Stability, Gloss and Surface Roughness of Removable Partial Dental Prosthetic Polymers.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Papathanasiou Ioannis, Papavasiliou George, Kamposiora Phophi, Zoidis Panagiotis

Аннотация

PURPOSE: To assess the effect of commonly used solutions on color stability, gloss, and surface roughness of removable partial dental prostheses polymers.

MATERIALS AND METHODS: Discs (n = 112) were made of a poly(etheretherketone) (PEEK) polymer, a polyamide, an acetal resin and a heat-cured poly(methylmethacrylate) PMMA acrylic resin polished according to manufacturers' instructions. Seven specimens of each material were immersed in coffee, red wine, coca cola and distilled water for 30 days at 37ο C. Changes of color (ΔΕ*) and color coordinates L*α*b* after immersion were calculated with a colorimeter. Changes in the values of gloss and surface roughness parameters (Sa, Sz, Str, Sdr, Sci, Svi) were also measured. Two-way ANOVA and pairwise comparisons were used to evaluate the effect of material and staining solution on parameter value alterations (α = 0.05).

RESULTS: The two-way ANOVA revealed that the interaction between material and staining solution significantly affected color changes after immersion [F(9,96) = 44.67, p < 0.001]. PEEK presented the lowest color change (ΔΕ* = 3.83 ± 2) while polyamide had the highest color change overall (ΔΕ* = 14.59 ± 8.65) (p < 0.001). Coffee caused the highest color (ΔΕ* = 13.08 ± 6.98) and gloss changes (ΔG = -6.36 ± 19.2 GU) among different solutions (p < 0.001). PEEK showed the highest alteration of gloss (ΔG = -11.31 ± 15.49 GU), with significant difference with the other three materials (p < 0.001). Insignificant interaction of material and immersing solution was found for surface roughness parameters (p > 0.05).

CONCLUSIONS: Among the materials tested, PEEK seemed to be the most stable material when subjected to common, everyday staining solutions. Therefore, PEEK could be a viable solution for an RPDP framework fabrication, expanding the material list of prosthetic options. Further research and clinical trials are required to confirm the above statement.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты