MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0017626

Медицинская библиотека · PloS one · 2011

Evaluation of the efficacy and safety of rivaroxaban using a computer model for blood coagulation.

Burghaus Rolf, Coboeken Katrin, Gaub Thomas, Kuepfer Lars, Sensse Anke, Siegmund Hans-Ulrich, Weiss Wolfgang, Mueck Wolfgang, Lippert Joerg

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Rivaroxaban is an oral, direct Factor Xa inhibitor approved in the European Union and several other countries for the prevention of venous thromboembolism in adult patients undergoing elective hip or knee replacement surgery and is in advanced clinical development for the treatment of thromboembolic disorders. Its mechanism of action is antithrombin independent and differs from that of other anticoagulants, such as warfarin (a vitamin K antagonist), enoxaparin (an indirect thrombin/Factor Xa inhibitor) and dabigatran (a direct thrombin inhibitor). A blood coagulation computer model has been developed, based on several published models and preclinical and clinical data. Unlike previous models, the current model takes into account both the intrinsic and extrinsic pathways of the coagulation cascade, and possesses some unique features, including a blood flow component and a portfolio of drug action mechanisms. This study aimed to use the model to compare the mechanism of action of rivaroxaban with that of warfarin, and to evaluate the efficacy and safety of different rivaroxaban doses with other anticoagulants included in the model. Rather than reproducing known standard clinical measurements, such as the prothrombin time and activated partial thromboplastin time clotting tests, the anticoagulant benchmarking was based on a simulation of physiologically plausible clotting scenarios. Compared with warfarin, rivaroxaban showed a favourable sensitivity for tissue factor concentration inducing clotting, and a steep concentration-effect relationship, rapidly flattening towards higher inhibitor concentrations, both suggesting a broad therapeutic window. The predicted dosing window is highly accordant with the final dose recommendation based upon extensive clinical studies.

Для цитирования: Burghaus Rolf, Coboeken Katrin, Gaub Thomas, Kuepfer Lars, Sensse Anke, Siegmund Hans-Ulrich, Weiss Wolfgang, Mueck Wolfgang, Lippert Joerg. Evaluation of the efficacy and safety of rivaroxaban using a computer model for blood coagulation.. PloS one. 2011. DOI: 10.1371/journal.pone.0017626.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.