MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2215/cjn.03750708

Медицинская библиотека · Clinical journal of the American Society of Nephrology : CJASN · 2009

MRI-based kidney volume measurements in ADPKD: reliability and effect of gadolinium enhancement.

Bae Kyongtae T, Tao Cheng, Zhu Fang, Bost James E, Chapman Arlene B, Grantham Jared J, Torres Vicente E, Guay-Woodford Lisa M, Meyers Catherine M, Bennett William M, Consortium for Radiologic Imaging Studies Polycystic Kidney Disease

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

To evaluate the inter- and intrareader reliability and the effect of gadolinium enhancement on kidney volume measurements obtained from pre- and postgadolinium T1 MR images in patients with autosomal dominant polycystic kidney disease (ADPKD).

DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Twenty subjects were randomly selected with approximately equal frequency from three kidney-size groups. Pre- and postgadolinium 3D T1 (pre-T1, post-T1) MR images were obtained. The stereology method was applied to segment and measure kidney volumes. The measurement process was repeated at two-wk intervals by two radiologists. Reliability was assessed with correlation coefficients. Intra- and inter-reader bias and measure differences were assessed with paired T-tests. The size effect on the pre- and post-T1 measurements was evaluated with one-way ANOVA.

RESULTS

The intra- and inter-reader reliability was extremely high in all measurements. No systematic intrareader bias but a small inter-reader bias for the post-T1 measurements was observed. All kidney volumes measured on the pre- and post-T1 images were highly correlated with each other for both readers. The post-T1 volumes were significantly higher than pre-T1 volumes. While the post-pre volume differences were relatively constant across the three kidney-size groups, the post-pre percent volume differences were significantly smaller as the size of the kidney increased.

CONCLUSIONS

Kidney volume measurements can be made with minimum intra- and inter-reader variability on both pre- and post-T1 MR images. Kidney volumes measured on the pre-T1 were smaller than those on post-T1, and percent differences between pre-T1 and post-T1 kidney volumes decreased with increasing kidney size.

Для цитирования: Bae Kyongtae T, Tao Cheng, Zhu Fang, Bost James E, Chapman Arlene B, Grantham Jared J, Torres Vicente E, Guay-Woodford Lisa M, Meyers Catherine M, Bennett William M, Consortium for Radiologic Imaging Studies Polycystic Kidney Disease. MRI-based kidney volume measurements in ADPKD: reliability and effect of gadolinium enhancement.. Clinical journal of the American Society of Nephrology : CJASN. 2009. DOI: 10.2215/cjn.03750708.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.