Portable, real-time 3D ultrasound for operator-independent breast imaging.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nayeem Md Osman Goni, Viswanath Shrihari, Yoon Hyeokjun, Shah Aastha, Sadat David, Marcus Colin, Chandrakasan Anantha P, Ozmen Tolga, Dagdeviren Canan

Аннотация

Breast cancer screening and longitudinal monitoring require imaging technologies that are portable, operator-independent, and suitable for frequent use, a capability not fully met by mammography or conventional ultrasound. We present a three-dimensional (3D) portable ultrasound system for real-time examination (3D PURE) that overcomes key limitations in volumetric breast imaging through advances in transducer design, acoustic materials, and adaptive beamforming. A box-array design incorporating a corner-gap offset geometry suppresses peak crosstalk (by 3.73 dB at the corner-most element), prevents preamplifier saturation, and supports higher transmit voltages (up to 24 V). A custom flowable backing layer (impedance 6.12 MRayl; attenuation 7.56 dB mm-1 MHz-1) integrates around fragile wirebonds, reduces inter-element crosstalk by ~4.5 dB throughout the array, and improves axial and lateral/elevational resolutions by ~200 µm and ~70 µm, respectively. Layered Aberration-Correction Reconstruction (LACR), an adaptive 3D beamformer, compensates for heterogeneous speed-of-sound (SoS) in the breast, reducing depth localization error by 2 mm and aberration defocusing by 70 µm on average at a 5 cm depth. Nine of the ten participants in an in vitro study showed improved microtarget detection efficiency with 3D PURE relative to a conventional 2D system (p = 0.0215), analogous to detection of microcalcifications. These results, combined with in vivo imaging validation of various phenotypes, highlight the potential of 3D PURE for reliable breast imaging. Furthermore, a vision-guided computer interface, MyFUS, ensures self-guided, user-friendly, and operator-independent probe positioning for longitudinal monitoring.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты