Portable, real-time 3D ultrasound for operator-independent breast imaging.

Nayeem Md Osman Goni, Viswanath Shrihari, Yoon Hyeokjun, Shah Aastha, Sadat David, Marcus Colin, Chandrakasan Anantha P, Ozmen Tolga, Dagdeviren Canan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Breast cancer screening and longitudinal monitoring require imaging technologies that are portable, operator-independent, and suitable for frequent use, a capability not fully met by mammography or conventional ultrasound. We present a three-dimensional (3D) portable ultrasound system for real-time examination (3D PURE) that overcomes key limitations in volumetric breast imaging through advances in transducer design, acoustic materials, and adaptive beamforming. A box-array design incorporating a corner-gap offset geometry suppresses peak crosstalk (by 3.73 dB at the corner-most element), prevents preamplifier saturation, and supports higher transmit voltages (up to 24 V). A custom flowable backing layer (impedance 6.12 MRayl; attenuation 7.56 dB mm-1 MHz-1) integrates around fragile wirebonds, reduces inter-element crosstalk by ~4.5 dB throughout the array, and improves axial and lateral/elevational resolutions by ~200 µm and ~70 µm, respectively. Layered Aberration-Correction Reconstruction (LACR), an adaptive 3D beamformer, compensates for heterogeneous speed-of-sound (SoS) in the breast, reducing depth localization error by 2 mm and aberration defocusing by 70 µm on average at a 5 cm depth. Nine of the ten participants in an in vitro study showed improved microtarget detection efficiency with 3D PURE relative to a conventional 2D system (p = 0.0215), analogous to detection of microcalcifications. These results, combined with in vivo imaging validation of various phenotypes, highlight the potential of 3D PURE for reliable breast imaging. Furthermore, a vision-guided computer interface, MyFUS, ensures self-guided, user-friendly, and operator-independent probe positioning for longitudinal monitoring.

Для цитирования: Nayeem Md Osman Goni, Viswanath Shrihari, Yoon Hyeokjun, Shah Aastha, Sadat David, Marcus Colin, Chandrakasan Anantha P, Ozmen Tolga, Dagdeviren Canan. Portable, real-time 3D ultrasound for operator-independent breast imaging.. Nature communications. 2026. DOI: 10.1038/s41467-026-74708-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.