m+Medelevator.RU
← Поиск публикаций
Heart rhythm · 2020

Three-dimensional guided selective right ventricular septal pacing preserves ventricular systolic function and synchrony in pediatric patients.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Silvetti Massimo Stefano, Pazzano Vincenzo, Battipaglia Irma, Saputo Fabio Anselmo, Mizzon Chiara, Gimigliano Fabrizio, Ammirati Antonio, Ravà Lucilla, Drago Fabrizio

Аннотация

BACKGROUND: Nonfluoroscopic 3-dimensional (3D) electroanatomic mapping systems (EAMs) have been developed to guide cardiac catheter navigation and reduce fluoroscopy. Selective right ventricular (RV) septal pacing could prevent pacing-induced left ventricular (LV) dysfunction.

OBJECTIVE: The purpose of this study was to determine whether EAM-guided selective RV septal pacing preserves LV contractility/synchrony in pediatric patients with complete atrioventricular block (CAVB) and no other congenital heart defects.

METHODS: Prospective analysis of children/adolescents who underwent EAM-guided selective RV pacing was performed. A 3D pacing map guided ventricular lead implantation at septal sites with narrow paced QRS. Serial echocardiograms were obtained after pacemaker implantation to monitor for function (volumes, ejection fraction [EF], global longitudinal/circumferential strain) and synchrony (interventricular mechanical delay, septal to posterior wall motion delay, systolic dyssynchrony index). Data are reported as median (25th-75th percentile).

RESULTS: Thirty-two CAVB patients (age 9.8 [7.0-14.0] years; 11 with a previous pacing system) underwent selective RV septal pacing (13 DDD, 19 VVIR pacemaker; midseptum 22, parahisian 7, RV outflow tract 3) with narrow paced QRS (110 [100-120] ms) and low radiation exposure. Follow-up over 24 (5-33) months showed preserved LV function and synchrony, without significant differences between pacing sites (midseptum-parahisian) and mode (VVIR-DDD). EF decreased after implantation in patients without previous pacing, although values were mainly within normal limits. Three parahisian patients underwent early lead repositioning.

CONCLUSION: EAM-guided selective RV septal pacing is a feasible technique associated with preserved LV systolic function and synchrony and low radiation exposure in pediatric patients with CAVB.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты