MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jat/bku066

Медицинская библиотека · Journal of analytical toxicology · 2014

Multi-drug and metabolite quantification in postmortem blood by liquid chromatography-high-resolution mass spectrometry: comparison with nominal mass technology.

Rosano Thomas G, Na Seo, Ihenetu Kenneth, Swift Thomas A, Wood Michelle

СтатьяПеревод в очереди

Аннотация

High-resolution mass spectrometry (HRMS) is being applied in postmortem drug screening as an alternative to nominal mass spectrometry, and additional evaluation in quantitative casework is needed. We report quantitative analysis of benzoylecgonine, citalopram, cocaethylene, cocaine, codeine, dextromethorphan, dihydrocodeine, diphenhydramine, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, hydrocodone, hydromorphone, meperidine, methadone, morphine, oxycodone and oxymorphone in postmortem blood by ultra-performance liquid chromatography (UPLC)-MS(E)/time-of-flight (TOF). The method employs analyte-matched deuterated internal standardization and MS(E) acquisition of precursor and product ions at low (6 eV) and ramped (10-40 eV) collision energies, respectively. Quantification was performed using precursor ion data obtained with a mass extraction window of ± 5 ppm. Fragment and residual precursor ion acquisitions at ramped collision energies were evaluated as additional analyte identifiers. Extraction recovery of >60% and matrix effect of <20% were determined for all analytes and internal standards. Defined limits of detection (10 ng/mL) and quantification (25 ng/mL) were validated along with a linearity analytical range of 25-3,000 ng/mL (R(2) > 0.99) for all analytes. Parallel UPLC-MS(E)/TOF and UPLC-MS/MS analysis showed comparable precision and bias along with concordance of 253 positive (y = 1.002x + 1.523; R(2) = 0.993) and 2,269 negative analyte findings in 159 postmortem cases. Analytical performance and correlation studies demonstrate accurate quantification by UPLC-MS(E)/TOF and extended application of HRMS in postmortem casework.

Для цитирования: Rosano Thomas G, Na Seo, Ihenetu Kenneth, Swift Thomas A, Wood Michelle. Multi-drug and metabolite quantification in postmortem blood by liquid chromatography-high-resolution mass spectrometry: comparison with nominal mass technology.. Journal of analytical toxicology. 2014. DOI: 10.1093/jat/bku066.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.