MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.0906-6705.2005.00341.x

Медицинская библиотека · Experimental dermatology · 2005

Stratum corneum hydration and flexibility are useful parameters to indicate clinical severity of congenital ichthyosis.

Tomita Yuki, Akiyama Masashi, Shimizu Hiroshi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

To determine any correlation between the stratum corneum barrier function and the phenotypic severity of congenital ichthyosis, we studied stratum corneum hydration, flexibility, thickness and transepidermal water loss (TEWL) in patients with congenital ichthyosis. Seven patients with congenital ichthyosis aged 2-46 years and age-matched controls were included in the present study. We divided seven patients into two groups; patients with non-bullous type (non-bullous congenital ichthyosiform erythroderma patients) and patients with the bullous type of congenital ichthyosis (bullous congenital ichthyosiform erythroderma and ichthyosis bullosa of Siemens). Stratum corneum hydration, thickness and flexibility were measured using a Corneometer ASA-M2. The stratum corneum thickness was also examined using a skin biopsy technique. TEWL was measured using Evaporimeter AS-TW1. The clinical severity of ichthyosis phenotype was evaluated using a visual analogue scale (VAS). Stratum corneum hydration and flexibility were significantly reduced in both congenital ichthyosis patient groups. Stratum corneum thickness was significantly increased in both groups. In the patient group with non-bullous congenital ichthyosis, significant negative correlations were confirmed between the VAS score and stratum corneum hydration and between the VAS score and flexibility. A significant, positive correlation was also observed between the VAS score and stratum corneum thickness. There was a positive correlation between the VAS score and TEWL on both the extensor and flexor sides of the forearm and back. We conclude that stratum corneum hydration, flexibility and thickness measured by the corneometer, and TEWL on the arm may be a useful indicator of the severity of ichthyosis phenotype.

Для цитирования: Tomita Yuki, Akiyama Masashi, Shimizu Hiroshi. Stratum corneum hydration and flexibility are useful parameters to indicate clinical severity of congenital ichthyosis.. Experimental dermatology. 2005. DOI: 10.1111/j.0906-6705.2005.00341.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.