MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpeds.2010.08.032

Медицинская библиотека · The Journal of pediatrics · 2011

Anosmia predicts hypogonadotropic hypogonadism in CHARGE syndrome.

Bergman Jorieke E H, Bocca Gianni, Hoefsloot Lies H, Meiners Linda C, van Ravenswaaij-Arts Conny M A

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To test the hypothesis that a smell test could predict the occurrence of hypogonadotropic hypogonadism (HH) in patients with CHARGE syndrome, which is a variable combination of ocular coloboma, heart defects, choanal atresia, retardation of growth/development, genital hypoplasia, and ear anomalies or hearing loss caused by mutations in the CHD7 (chromodomain helicase DNA binding protein 7) gene.

STUDY

DESIGN

We performed endocrine studies and smell testing (University of Pennsylvania Smell Identification Test) in 35 adolescent patients with molecularly confirmed CHARGE syndrome.

RESULTS

Complete data on smell and puberty were available for 15 patients; 11 patients had both anosmia and HH, whereas 4 patients had normosmia/hyposmia and spontaneous puberty. In addition, 7 boys were highly suspected of having HH (they were too young for definite HH diagnosis, but all had cryptorchidism, micropenis, or both) and had anosmia. The type of CHD7 mutation could not predict HH because a father and daughter with the same CHD7 mutation were discordant for HH and anosmia.

CONCLUSION

Anosmia and HH were highly correlated in our cohort, and therefore smell testing seems to be an attractive method for predicting the occurrence of HH in patients with CHARGE syndrome. The use of this test could prevent delay of hormonal pubertal induction, resulting in an age-appropriate puberty.

Для цитирования: Bergman Jorieke E H, Bocca Gianni, Hoefsloot Lies H, Meiners Linda C, van Ravenswaaij-Arts Conny M A. Anosmia predicts hypogonadotropic hypogonadism in CHARGE syndrome.. The Journal of pediatrics. 2011. DOI: 10.1016/j.jpeds.2010.08.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.