MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/2150135114563937

Медицинская библиотека · World journal for pediatric & congenital heart surgery · 2015

Doppler-derived flow pattern in the descending aorta does not predict systemic to pulmonary arterial collateral flow in patients with single ventricle palliation: a cross-sectional study.

Di Maria Michael V, Cohen Meryl S, Harris Matthew A, Fogel Mark A, Whitehead Kevin K

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Children with single ventricle heart disease are at risk for developing systemic to pulmonary arterial collateral vessels that adversely impact short-term outcomes, although the effect on long-term outcomes remains unclear. Collateral flow (CollF) can be quantified using cardiac magnetic resonance (CMR) flow quantification. The velocity-time integral (VTI), obtained from spectral Doppler tracings, has been used in "runoff" lesions like aortic regurgitation to quantify insufficiency. We hypothesized that the VTI ratio of the proximal descending aorta (DAo) after cavopulmonary anastomosis (CPA) would estimate CollF.

METHODS

A retrospective cross-sectional study was conducted. Patients who had a superior CPA or total CPA and underwent CMR between April 2008 and December 2012 were included. Those with greater than trivial semilunar valve insufficiency or aortic arch obstruction were excluded. In a subset (n = 88), spectral Doppler tracings of the DAo were analyzed to determine the VTI ratio. In another subset (n = 112), CMR was used to determine the ratio of retrograde to antegrade flow in the DAo.

RESULTS

There was no linear correlation between VTI ratio and CollF (r (2) = .006, P = .46). There was a weakly positive correlation with CollF (r (2) = .07, P = .007) and the CMR measured ratio of retrograde to antegrade flow. Holodiastolic flow reversal by echo did not predict higher CollF (P = .40), but those with holodiastolic flow reversal by CMR had significantly higher CollF (P = .04).

CONCLUSIONS

The ratio of reverse to forward flow in the DAo as determined by Doppler echo does not accurately reflect CollF in children with single ventricle after CPA.

Для цитирования: Di Maria Michael V, Cohen Meryl S, Harris Matthew A, Fogel Mark A, Whitehead Kevin K. Doppler-derived flow pattern in the descending aorta does not predict systemic to pulmonary arterial collateral flow in patients with single ventricle palliation: a cross-sectional study.. World journal for pediatric & congenital heart surgery. 2015. DOI: 10.1177/2150135114563937.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.