Skeletal facial asymmetry: reliability of manual and artificial intelligence-driven analysis.

Kazimierczak Natalia, Kazimierczak Wojciech, Serafin Zbigniew, Nowicki Paweł, Jankowski Tomasz, Jankowska Agnieszka, Janiszewska-Olszowska Joanna

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To compare artificial intelligence (AI)-driven web-based platform and manual measurements for analysing facial asymmetry in craniofacial CT examinations.

METHODS

The study included 95 craniofacial CT scans from patients aged 18-30 years. The degree of asymmetry was measured based on AI platform-predefined anatomical landmarks: sella (S), condylion (Co), anterior nasal spine (ANS), and menton (Me). The concordance between the results of automatic asymmetry reports and manual linear 3D measurements was calculated. The asymmetry rate (AR) indicator was determined for both automatic and manual measurements, and the concordance between them was calculated. The repeatability of manual measurements in 20 randomly selected subjects was assessed. The concordance of measurements of quantitative variables was assessed with interclass correlation coefficient (ICC) according to the Shrout and Fleiss classification.

RESULTS

Erroneous AI tracings were found in 16.8% of cases, reducing the analysed cases to 79. The agreement between automatic and manual asymmetry measurements was very low (ICC < 0.3). A lack of agreement between AI and manual AR analysis (ICC type 3 = 0) was found. The repeatability of manual measurements and AR calculations showed excellent correlation (ICC type 2 > 0.947).

CONCLUSIONS

The results indicate that the rate of tracing errors and lack of agreement with manual AR analysis make it impossible to use the tested AI platform to assess the degree of facial asymmetry.

Для цитирования: Kazimierczak Natalia, Kazimierczak Wojciech, Serafin Zbigniew, Nowicki Paweł, Jankowski Tomasz, Jankowska Agnieszka, Janiszewska-Olszowska Joanna. Skeletal facial asymmetry: reliability of manual and artificial intelligence-driven analysis.. Dento maxillo facial radiology. 2024. DOI: 10.1093/dmfr/twad006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.