m+Medelevator.RU
← Поиск публикаций
Swiss medical weekly · 2001

Factors affecting the efficiency of aerosol therapy with pressurised metered-dose inhalers through plastic spacers.

Клиническое исследованиеКонтролируемое клиническое исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chuffart A A, Sennhauser F H, Wildhaber J H, Swiss Paediatric Respiratory Physiology Research Group

Аннотация

AIM: The main objective of this study was to compare the in vitro delivery of salbutamol from a chlorofluorocarbon(CFC)-propelled pressurised metered-dose inhaler (pMDI) versus a newly developed hydrofluoroalkane(HFA)-propelled pMDI through various spacers. In addition, we aimed to study the effect on bronchodilator response when using an optimal pMDI/spacer combination for aerosol delivery compared to a suboptimal combination.

METHODS: Particle size distribution and output from salbutamol pMDIs containing either CFC propellants (Ventolin) or HFA propellants (Airomir) were measured using a multistage liquid impinger (MSLI) and compared to that through both detergent-coated (non-static) or untreated (static) large volume (Nebuhaler, Volumatic) and small volume (Aerochamber) plastic spacers. Flow-volume curves (FEV1) were obtained from twelve asthmatic children with known significant bronchodilator response (8 males), aged 13-17 years, randomly inhaling salbutamol from a CFC-pMDI through a static spacer (Nebuhaler) and from an HFA-pMDI through a non-static spacer (Nebuhaler).

RESULTS: In vitro output of particles in the respirable range (< 6.8 microns) from HFA-pMDIs was significantly higher than that from CFC-pMDIs using various spacers. Removal of electrostatic charge increased output from CFC- and HFA-pMDIs through all spacers by 17-82%. The mean (SD) bronchodilator response after inhalation of salbutamol from a CFC-pMDI through a static spacer was 7.1% (6.3%) compared to 17.5% (7.9%) after inhalation from an HFA-pMDI through a non-static spacer (p = 0.002).

CONCLUSIONS: Use of a newly developed HFA-propelled pMDI greatly improves drug delivery through spacers compared to a CFC-propelled pMDI. However, electrostatic charge in plastic spacers remains the key determinant limiting delivery of salbutamol from a pMDI through spacers, and can be reduced by soaking the spacer in a household detergent. Using an optimal pMDI/spacer combination leads to a significantly improved bronchodilator response.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты