MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jsr.14373

Медицинская библиотека · Journal of sleep research · 2024

Pitolisant 40 mg for excessive daytime sleepiness in obstructive sleep apnea patients treated or not by CPAP: Randomised phase 3 study.

Dauvilliers Yves, Craig Sonya Elizabeth, Bonsignore Maria R, Barbé Ferran, Verbraecken Johan, Asin Jerryl, Georgiev Ognian, Tiholov Rumen, Caussé Christian, Lecomte Jeanne-Marie, Schwartz Jean-Charles, Lehert Philippe, Randerath Winfried, Pépin Jean-Louis, HAROSA III Study Group

СтатьяРандомизированное исследованиеКлиническое исследование III фазыМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Obstructive sleep apnea (OSA) syndrome commonly leads to excessive daytime sleepiness (EDS). Pitolisant, a selective histamine-3 receptor antagonist, is efficacious at doses up to 20 mg once daily in OSA treated or not with continuous positive airway pressure (CPAP). We assessed the efficacy and safety of pitolisant at doses up to 40 mg once daily in patients with moderate to severe OSA treated or not with CPAP therapy. In this phase 3, multicentre, randomised, double-blind, placebo-controlled clinical trial, patients with OSA were assigned 2:1 to receive pitolisant (according to an individual up-titration scheme, 10, 20 or 40 mg once daily) or placebo for 12 weeks. The primary endpoint was a change in the Epworth Sleepiness Scale (ESS) score from baseline to week 12. Secondary endpoints included a change in reaction time using the Oxford Sleep Resistance test (OSleR), Clinical Global Impression of Change (CGI-C), and Patient's Global Opinion of the Effect (PGOE) of study treatment. Overall, 361 patients (mean age 52.4 years, 77.3% male; mean apnea-hypopnea index [AHI] 27.0 events/h) were randomised to receive pitolisant (n = 242; 50% received CPAP) or placebo (n = 119; 48.7% CPAP). After the dose-adjustment phase (week 3), 88.8% of patients received pitolisant 40 mg. Compared with placebo, pitolisant produced a significant reduction in the ESS score at week 12 (least square mean difference -2.6 (95% CI: -3.4; -1.8; p < 0.001)) irrespective of CPAP use; and improved the reaction time on OSleR, CGI-C, and PGOE at week 12. Pitolisant was well tolerated; no new safety signals were identified. In conclusion, pitolisant up to 40 mg once daily was an effective treatment for EDS in patients with moderate to severe OSA irrespective of CPAP use.

Для цитирования: Dauvilliers Yves, Craig Sonya Elizabeth, Bonsignore Maria R, Barbé Ferran, Verbraecken Johan, Asin Jerryl, Georgiev Ognian, Tiholov Rumen, Caussé Christian, Lecomte Jeanne-Marie, Schwartz Jean-Charles, Lehert Philippe, Randerath Winfried, Pépin Jean-Louis, HAROSA III Study Group. Pitolisant 40 mg for excessive daytime sleepiness in obstructive sleep apnea patients treated or not by CPAP: Randomised phase 3 study.. Journal of sleep research. 2024. DOI: 10.1111/jsr.14373.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.