MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s0004-27492010000200014

Медицинская библиотека · Arquivos brasileiros de oftalmologia · 2010

[Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].

Arraes Caroline, Endriss Daniela, Lobato Francisco, Arraes João, Ventura Marcelo

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon.

METHODS

The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy.

RESULTS

The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100%) eyes: in 12 eyes (70.6%) the visual acuity was better than 20/40; 4 (23.5%) ranged from 20/40 to 20/100, and 1 (5.9%) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9%). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases.

CONCLUSION

The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.

Для цитирования: Arraes Caroline, Endriss Daniela, Lobato Francisco, Arraes João, Ventura Marcelo. [Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].. Arquivos brasileiros de oftalmologia. 2010. DOI: 10.1590/s0004-27492010000200014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.