MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1210/jc.2010-1554

Медицинская библиотека · The Journal of clinical endocrinology and metabolism · 2010

A highly sensitive, high-throughput assay for the detection of Turner syndrome.

Rivkees Scott A, Hager Karl, Hosono Seiyu, Wise Anastasia, Li Peining, Rinder Henry M, Gruen Jeffrey R

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

OBJECTIVE

Turner syndrome (TS) occurs when an X-chromosome is completely or partially deleted or when X-chromosomal mosaicism is present. Girls with TS benefit from early diagnosis and treatment with GH; however, many girls with TS are not detected until after 10 yr of age, resulting in delayed evaluation and treatment.

METHODS

We developed a high-throughput test for TS, based on a quantitative method of genotyping to detect X-chromosome abnormalities. This test uses pyrosequencing to quantitate relative allele strength (RAS) from single-nucleotide polymorphisms using 18 informative single-nucleotide polymorphisms markers that span the X-chromosome and one marker for the detection of Y-chromosome material.

RESULTS

Cutoff ranges for heterozygous, homozygous, or out-of-range RAS values were established from a cohort of 496 males and females. Positive TS scoring criteria were defined as the presence of homozygosity for all 18 markers or the presence of at least one out-of-range RAS value. To determine the validity of this rapid test for TS detection, we undertook a large-scale study using DNA from 132 females without TS and 74 females with TS for whom karyotypes were available. TS was identified with 96.0% sensitivity and 97.0% specificity in this cohort. We also tested buccal swab DNA from a group of 19 females without TS and 69 females with TS. In this group, TS was identified with 97.1% sensitivity and 84.2% specificity.

CONCLUSIONS

These results demonstrate the validity of a high-throughput, pyrosequencing based test for the accurate detection of TS, providing a potential alternative to karyotype testing.

Для цитирования: Rivkees Scott A, Hager Karl, Hosono Seiyu, Wise Anastasia, Li Peining, Rinder Henry M, Gruen Jeffrey R. A highly sensitive, high-throughput assay for the detection of Turner syndrome.. The Journal of clinical endocrinology and metabolism. 2010. DOI: 10.1210/jc.2010-1554.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.